This routine-service checklist covers the Aqua Flo 475 PRO and 475BP PRO in the manufacturer’s 475/475BP PRO Series manual. Record the system label and match the stage or position with the installed part number and manual. The manufacturer specifies a potable feed. During an advisory, use known safe stored water as directed and follow the notice for your address. Canature Aqua Flo 475 specifications · CDC drinking water advisory guidance
Match the installed part
The standard four-stage configuration has a sediment prefilter, a COC-10 carbon prefilter, a membrane and a COC-10 carbon postfilter. The manufacturer lists GAC-10 and CB-10 as separate optional filters. The parts drawing groups the carbon cartridges under callouts 2/3. Identify prefilter and postfilter by function and compare what your system actually uses. Canature model and filter specifications · Canature manual, printed page 13 parts list
| Part to match by position and label | OEM number and routine service listing |
|---|---|
| Sediment prefilter marked SED-10. | 65010086 SED-10 sediment cartridge |
| Carbon prefilter or postfilter specified as COC-10, a 10-micron coconut carbon cartridge. | 65010088 COC-10 coconut carbon cartridge |
| Carbon position documented for the optional GAC-10 granular carbon cartridge. | 65010089 GAC-10 granular carbon cartridge |
| Membrane position documented for the 75 GPD TFC membrane. | 70010014 75 GPD TFC membrane |
If your parts record says CB-10, confirm the OEM part number for that separate optional carbon block. If your label only says “475,” capture the complete label and use the parts finder to confirm coverage.
Count your spares by position
Copy one line for each position before ordering.
| Position | Installed label and number | Last service | Matching spare already on hand |
|---|---|---|---|
| Sediment prefilter | ___ | ___ | ___ |
| Carbon prefilter | ___ | ___ | ___ |
| Membrane | ___ | ___ | ___ |
| Carbon postfilter | ___ | ___ | ___ |
Example. A 475BP PRO uses COC-10 at both carbon positions, both are due for service and you have one unopened, suitable 65010088 in your spares. Your record shows one more matching cartridge is needed for that service. If one position shows GAC-10 or CB-10, record it separately and confirm the installed configuration. Keep the record with the RO filter and membrane maintenance guide. Canature Aqua Flo 475 configuration
For more checklists and water outage guides, visit Emergency Water Prep.