Read the full model on the UV unit and compare it with the model column in the manual. Canature lists the same lamp and quartz sleeve numbers for GENH5-25 and GENH6-25. The model may be printed without spaces. This match covers the lamp and sleeve in the table. Match controllers, sensors and other parts against their own documentation. GEN H5 high-output specifications, printed page 23 · GEN H6 high-output specifications, printed page 23
| Full system label | Routine lamp | Routine quartz sleeve | Model evidence |
|---|---|---|---|
| GENH5-25 or GEN H5-25 | 40040021 (RL-600HO) | 40040044 (RQ-600) | Canature manual 910194, GENH5-25 column |
| GENH6-25 or GEN H6-25 | 40040021 (RL-600HO) | 40040044 (RQ-600) | Canature archive manual 910094, GENH6-25 column |
Canature’s tables supply the numeric OEM part references. The WPS listings pair them with the letter-number descriptions above. The lamp and sleeve are separate components. Check which one your service record calls for before ordering.
Use the label-to-order check
- Copy the full label. Record GEN, H, the series digit and the size suffix. Keep a photo of the system label and, if visible, the separate controller label.
- Line up three entries. Write the full model, the manual’s numeric part number and the listing SKU side by side. For a GENH6-25 sleeve, the result reads GENH6-25 / 40040044 / 40040044.
- Stop on a partial match. If the label only says “GEN” or “25,” gather more label information using the UV lamp and sleeve identification guide and send it through the parts finder. If the model is GENH5-15, use that model’s own table column. Canature GEN H5 model columns
Plan routine service while the installation and source are in normal use. If water safety is uncertain during a power outage, use known safe stored water and follow local health guidance. A model-matched spare is for service of installed equipment. CDC drinking water advisory guidance · Canature GEN operating information
For more checklists and water outage guides, visit Emergency Water Prep.