Identify an Aquatec pump by its complete model code and documented role before choosing a catalog result. A demand/delivery pump and an RO pressure-booster pump answer different system questions. “Aquatec 5800” alone leaves the role and configuration unresolved.
This guide separates the manufacturer's pump categories from the identities stated on three Water Parts Supply catalog records. It helps you compare the pump, an electrical accessory and a kit request without treating a series number as proof of compatibility.
What does delivery versus booster mean in the manufacturer reference?
| Manufacturer category | Role described by Aquatec | Identification boundary |
|---|---|---|
| Demand/Delivery Pumps | Water delivery, including moving purified water to a point of use or pressurizing water from an atmospheric tank. | Match the full model and its applicable data sheet. The category page lists several 5800 download configurations. |
| Pressure Booster Pumps | Inlet-pressure support for membrane use. Aquatec names its 6800 and 8800 booster families. | The same category also names 5800-series model 5858-2LM2-B534. Do not classify every 5800 as a delivery pump. |
Sources: Aquatec's Demand/Delivery Pumps overview and downloads and Pressure Booster Pumps overview. These are role references, not permission to add a pump or change a system's pressure. Retain any DDP or CDP designation together with every character of the model code.
Aquatec 550: select the matching configuration document
Aquatec's Demand/Delivery page lists separate 550-series downloads for 12VDC, 24VDC, 115VAC and 230VAC configurations. Record the complete pump code and its own electrical marking; “550” alone does not select the document or make another configuration's data sheet applicable. The category listing does not establish a Water Parts Supply 550 offer or kit.
Why does the complete code matter?
Aquatec's booster page explicitly identifies 5858-2LM2-B534, not simply “5800.” The delivery listing below instead carries 5851-7E12-J574 and a DDP5800 description. Those are different records. A shared series number or similar pump body does not make their model codes or roles equivalent.
Copy the actual pump label and the applicable system reference before comparing an offer. Keep voltage, AC/DC marking, connector designation and any stated duty/configuration in separate fields. A family overview cannot establish an unidentified model's electrical requirements or connections. A data sheet with a different full suffix is not exact-model evidence for the installed pump.
Which catalog identity are you comparing?
The following details are the current catalog's stated identities and selling units. The manufacturer category references above do not independently verify every suffix, electrical specification or included accessory in these offers.
| Exact catalog record | Identity stated in the listing | Component and unit | Question to resolve before selecting |
|---|---|---|---|
| 5851-7E12-J574 | Aquatec Delivery Pump DDP5800; the listing states 120V, constant speed and 3/8JG, with cord and mounting plate. | Pump; listed customer unit: single. | Does the installed system document this complete pump code and configuration? Confirm the exact package separately. |
| 30588000 | Aquatec Booster Pump — CDP8800 24VAC HF. | Pump; listed customer unit: single. | What complete manufacturer pump code and system reference establish the required version? “CDP8800” does not describe a complete kit. |
| 30590016 | Aquatec transformer described for an 8800-series booster pump, TACS 115VAC/60HZ. | Transformer; listed customer unit: single. | Which documented transformer and pump configuration match? The transformer listing is a separate component, not an included item inferred from the pump link. |
A retailer's supplier identifier and the complete manufacturer code belong in separate fields when they differ. The transformer wording identifies the listing being compared; it does not establish that this transformer is suitable for every 8800 variant or confirm a match to an unidentified installed pump.
Does a pump listing mean a booster kit?
Keep a pump, transformer, pressure switch and named kit distinct. Aquatec's booster overview separately names pressure switches among its related flow-control components. That component relationship does not establish the contents of a retailer kit or of either linked pump offer.
For a kit request, record the exact kit identifier and its stated included components. Do not infer a transformer or pressure switch from a pump photo, a series name or another product's description. “Single” identifies the selling unit of the particular listing; it does not mean a complete system or bundle.
Low-feed-water shutoff or pressurized-system shutoff?
A pressure-switch request needs its documented control role as well as its complete identifier. Aquatec's CDP-series guide distinguishes two optional controls:
- LPP: the manual's low-feed-water shutoff designation.
- PSW: the manual's pressurized-system shutoff designation.
Those are different function labels, not full accessory order codes or interchangeable switch specifications. A request for low-feed-water protection is therefore not answered merely by finding a system-pressure switch under the same pump brand. The document's optional-control list does not establish which accessory is fitted to your system or supplied in a retailer's kit.
Retain the exact accessory label and applicable system reference beside the pump code. If only “LPP,” “PSW” or a pump-family number is known, leave the order code, electrical/connection configuration and installed-system applicability unresolved until Aquatec or the system manufacturer confirms them. This distinction supplies no switch setting, wiring, relocation, test or bypass instruction.
Source: Aquatec IMI-102 Rev. F, 08/09, page 2, opening optional-controls paragraph. The dated document was rechecked October 18, 2026; it is not evidence of a current replacement or supersession.
30510000 / ERP1000: identify the permeate-pump role
Aquatec describes ERP1000 as a permeate pump powered by hydraulic energy from the RO concentrate stream. Its sheet states that no electricity is required and describes the pump moving product water into the storage tank. Keep that documented role separate from the feed-pressure booster and demand/delivery categories above.
The WPS 30510000 record is supplier-described as an ERP1000 permeate pump with 1/4-inch John Guest quick-connect ports and a mounting clip, with a customer unit of single. Record 30510000 as the catalog identifier and ERP1000 as the named manufacturer model; those are separate identification fields.
The manufacturer's role description does not confirm every accessory in a seller's package or establish that an unidentified RO system should receive this pump. Match the system's documented pump role, complete model and proposed supplied contents before selecting an offer. A permeate-pump reference is not a diagnosis for a change in RO delivery.
Source: Aquatec Permeate Pumps, ERP1000/ERP500 catalog sheet, printed page 12, and the linked supplier record, checked October 20, 2026 (America/Chicago). This reference makes no installed-output, water-saving, certification, retrofit, compatibility or availability claim.
Build the identification request
- Installed system identity and the document specifying the pump's role.
- Complete pump label, DDP/CDP designation where present, model code and suffix.
- Documented electrical and connection markings, copied without substituting values from a similar model.
- Exact catalog identifier and whether the request is for a pump, transformer, switch or specified kit.
- Listed selling unit, quantity and included components confirmed for that offer.
- Unreadable label, missing exact-model data sheet or undocumented substitution.
Use the parts identification and ordering guide for selling-unit questions. A change in RO water delivery is an observation to document in the RO low-flow worksheet; it does not identify a pump replacement or justify a pressure change. For an unresolved catalog identity, request part-identification help with the complete label and supporting reference.
Source and evidence boundary
Aquatec's linked category pages were checked October 14, 2026 and state no document revision. They support the role distinction and the specific booster counterexample. Linked catalog labels and selling units were checked separately on the same date. Exact installed-model compatibility, electrical suitability and retailer shipped contents still require their own documentation.
550 variable-speed request or a constant-speed pump offer?
Aquatec has a separate variable-speed 550 range; a 550-series listing is not automatically that configuration. The manufacturer's variable-speed page describes integrated electronic control to vary motor operation with demand and maintain pressure across outlets. It lists separate Aquajet 550 downloads for several electrical and flow configurations. That family description does not select an exact pump code.
WPS's 5513-1E12-J526 offer is instead supplier-described as 550, 4.9 GPM, 120V, constant speed, with cord and 1/2-inch FNPT connections. Its constant-speed wording is a material distinction for a variable-speed buying request. Do not transfer an Aquajet variable-speed curve or controller description to this offer because both names contain 550.
Keep the required control type, complete code, electrical designation, connections and applicable performance curve with the equipment request. A family download labelled 115VAC is not independent confirmation of the supplied 120V listing or its full suffix. Confirm the exact manufacturer cross-reference and supplied package before selection; this comparison establishes no interchangeable pump, retrofit or present stock.
Sources checked October 20, 2026: Aquatec's Variable Speed Pumps and Demand/Delivery Pumps pages, and the linked WPS offer. No publication dates stated on the manufacturer pages. No wiring, pressure adjustment or installation instructions are supplied.
What does the 550-series 4.9 GPM sheet actually cover?
Aquatec's 115VAC 4.9 GPM data sheet identifies its model pattern as 55XX-XX12-B526. Its 55X3 performance column shows approximately 4.90 GPM at open discharge and 2.45 GPM at 70 PSI, measured with a flooded inlet at 0 PSI, water and ambient temperature of 70°F, and voltage controlled at 115VAC. The headline flow is therefore not a constant flow at every discharge pressure.
The sheet's B526 pattern differs from the WPS-listed 5513-1E12-J526 suffix above. These family test values do not establish that offer's exact curve, electrical equivalence or duty rating. Obtain the matching full-code manufacturer reference before using a curve for selection. Source checked October 21, 2026; no document revision date established.