Fleck 62048-01 vs 62048-02: Match Your Meter Kit

Fleck 2-inch stainless meter kit chart: 62048-01 is standard range; 62048-02 is extended range, with matching NPT and BSP meter numbers.

Order Fleck 62048-01 for a documented 2-inch stainless-steel meter in the standard range. Order 62048-02 for the same documented meter family in the extended range. Confirm the installed meter's complete assembly number or range documentation before choosing. The valve model and the 2-inch pipe size alone do not establish which kit fits.

Match the installed meter to the service kit

Fleck 2-inch stainless-steel inline meter assembly and service kit cross-reference
Installed meter assembly number Range Matching service kit
61934-10 (NPT) or 61934-20 (BSP) Standard Fleck 62048-01 standard-range kit
61934-11 (NPT) or 61934-21 (BSP) Extended Fleck 62048-02 extended-range kit

The cross-reference pairs item 1 (service kit) and item 2 (complete meter assembly) by range in the Pentair Fleck 2900S service manual, printed page 32. The table does not say every 2900S has one of these meters installed.

What to check before ordering

  1. Read the meter record first. Use the installed meter identifier, original equipment schedule, or service record. Note the full 61934 suffix where documented. If a prior meter replacement makes the old equipment record unreliable, verify it against the installed assembly before ordering.
  2. Match material and size. These kits apply to the documented 2-inch stainless-steel assembly. Page 31 of the same Pentair manual lists the 2-inch brass meter separately; use the dedicated parts list for that assembly rather than assuming it takes the stainless kit.
  3. Check range separately from thread type. NPT and BSP versions appear in both ranges. A 61934-20 is BSP standard, while a 61934-21 is BSP extended. Knowing the thread type is not enough to pick a kit.
  4. Confirm whether the job calls for a kit or complete meter. The service kit is not the 61934 inline meter assembly or the separately listed union. Order a kit only if the documented repair calls for the kit. Use the service call parts checklist to record and pack the exact number.

When not to choose either kit yet

If all you have is “Fleck 2900S” or “2-inch meter,” stop there. Take photos of the installed meter and any markings, note the complete valve model and timer, and record any prior replacement part number. Send those details through Find My Part if the range or assembly is still unknown. Once confirmed, compare the exact selling unit and package with the parts ordering guide. For mechanical service, follow the applicable Pentair manual, including its meter dome and union orientation instructions where applicable.

Back to blog