Before ordering filters for several units, open one work order per installed system. The move-out date is a chance to check what is due, not a reason to replace every cartridge. For confirmed four-vessel Aqua Flo Platinum 1240 systems, tally the verified sediment and carbon positions separately, then check whether the service team already has the correct sump wrench.
Separate the unit work order from the purchase order
- At walk-through: Record the unit, complete under-sink model, vessel count, and dated invoice for work already performed. Have maintenance verify the cartridge numbers for positions due. Do not open a pressurized housing to read a label.
- At approval: Mark each position replace, retain, or verify. Count only approved replacements with exact matches. A system with an unclear label or previous modification stays out of the parts count.
- At closeout: Record the actual parts used, service date, technician, and follow-up items. Hand off the current service record to the incoming occupant according to your property's process.
Which Aqua Flo 1240 parts go on the order?
The Canature Aqua Flo 1240 model page separates three- and four-vessel systems. Its replacement-kit sheet 80157018, Rev. 3 lists the following contents under 41407013. The manufacturer kit is a contents reference; the Water Parts Supply listings below are individual items. This is not a universal list for every 1240 or a kit purchase.
| Item | Matching listing | How to count |
|---|---|---|
| String-wound sediment | 41400008 sediment prefilter | One single for each matching sediment position approved for replacement. |
| Carbon block | 41400009 carbon pre/post filter | Count each matching pre- or post-filter position separately. Two positions due means two singles. |
| Sump wrench | 21401240 1240 sump wrench | Check the shared tool cart before buying. Do not count the wrench as a consumable for every unit. |
The manufacturer kit sheet does not list a membrane in 41407013. If stage 3 or another membrane position needs work, have the technician verify the separate membrane specification and service need before adding anything. An unfamiliar vessel count or a matching cap color is not enough to select a cartridge.
Print or copy the turnover lines
| Unit and installed label | Position and verified part | Decision and count | Closeout |
|---|---|---|---|
| ___ | ___ | Replace / retain / verify; ___ units | Installed item, date, technician: ___ |
| ___ | ___ | Replace / retain / verify; ___ units | Installed item, date, technician: ___ |
Example: Unit 2A needs verified sediment and both matching carbon positions serviced; 2B needs only one verified carbon filter; 2C has an unreadable label. The purchase order is one 41400008 and three 41400009 singles. Leave 2C on verify and skip a wrench purchase if the shop already has the correct model.
Use the part finder for an unresolved label, the RO maintenance record for future service, and the rental-property spares guide if you also keep a separate outage-readiness inventory.