Identify the complete housing model before choosing a head, sump, seal, clamp or fitting. A seal is not universal simply because its diameter or appearance seems similar.
Identification checklist
- Photograph the housing label and record the complete model and material marking.
- Identify whether the requested piece is a body, head, sump, seal, clamp, wrench or connection component.
- Record every documented inlet/outlet size and connection designation.
- Match the exact manufacturer number; do not infer seal fitment across housing series.
Example part identifiers
These examples identify documented parts, not universal fitment.
- HBCJ170 — HBCJ170 HydroScientific Band Clamp 170 Series Jumbo Housing - 2 Inch Inlet/Outlet, 304SS
- HBCJ40 — HBCJ40 HydroScientific Band Clamp 40 Series Jumbo Housing - 2 Inch Inlet/Outlet, 304SS
- HBCJ90 — HBCJ90 HydroScientific Band Clamp 90 Series Jumbo Housing - 2 Inch Inlet/Outlet, 304SS
Match the housing model, ports and pressure-relief option
A housing model identifies more than a nominal cartridge length. Pentair 310053 Rev F JA23, page 2, lists these Big Blue configurations separately:
| Housing number | Listed length | Inlet/outlet | Pressure relief (PR) |
|---|---|---|---|
| 150238 | #10 | 1-inch NPT | Without PR |
| 150236 | #20 | 1-1/2-inch NPT | Without PR |
| 150235 | #20 | 1-1/2-inch NPT | With PR |
Record the complete housing number, family, length, port/thread designation and PR marking before looking up a sump, seal, wrench or cartridge. The housing numbers above are distinct from the accessory identifiers below.
Choose the cartridge-identification route after the housing
The Big Blue sheet describes 10- and 20-inch housings accepting 4-1/2-inch-diameter cartridges. The separate 3G Standard sheet, 310103 REV F DE17, page 1, describes 10- and 20-inch housings with a 2-1/4- to 3-1/8-inch cartridge-diameter range. A shared nominal length does not establish a cartridge match.
Keep the installed family and exact model with your record, then use the existing cartridge size, end-configuration and identifier checklist. This comparison supplies identification context, not an installation procedure or a compatibility guarantee.
Manufacturer sheets checked October 14, 2026. The cited revisions identify the evidence reviewed.
Does “Big Blue” mean a carbon filter, and what do 10 and 20 describe?
In the Pentair sheet used here, Big Blue names a housing family; the installed cartridge supplies the filtration medium. The sheet describes 10- and 20-inch housings accepting 4½-inch-diameter cartridges. A 10- or 20-inch label is therefore not a micron rating, a carbon designation or a contaminant-reduction claim. Use the exact housing model and its documented cartridge requirements together.
A sediment element and a carbon element can have different treatment roles even when their format labels look similar. Use the sediment-versus-carbon explanation and named cartridge references to keep the medium separate from the housing. Neither a blue sump nor the family name establishes what an unidentified installed cartridge does.
Is maximum housing pressure the same as pressure drop?
No. Pentair lists a maximum operating-pressure limit separately from its initial pressure-drop figures at a stated flow. These two named examples illustrate the distinction:
| Model and listed length | Inlet/outlet; pressure relief | Maximum housing pressure | Initial pressure drop at stated flow |
|---|---|---|---|
| 150238, #10 | 1-inch NPT; without PR | 100 psi | 1 psi at 15 gpm |
| 150234, #20 | 1-inch NPT; without PR | 90 psi | 1 psi at 15 gpm |
The matching pressure-drop entries do not make the maximum-pressure limits identical. They also do not establish the installed cartridge's reduction capacity, pressure loss or complete-system performance. Retain each field's model, units and conditions; these values are not recommended operating settings or limits to transfer to another housing family.
Source: Pentair 310053 Rev F JA23, pages 1–2, checked October 20, 2026. Confirm the complete installed model and applicable system instructions before selecting a part. No current Water Parts Supply housing offer, installed fit or service procedure is established by these manufacturer examples.
Pentair Big Blue: O-ring and wrench identifiers
Pentair's Big Blue and Big Black housing specification sheet, 310053 Rev F JA23, page 2, lists the following accessories. Use these entries to check an identifier after confirming the installed housing belongs to the documented family.
| Manufacturer number | Accessory listed by Pentair | Identification check |
|---|---|---|
| 151122 | EPDM O-ring for Big Blue | Confirm the exact housing model and applicable parts instructions; appearance alone does not establish a seal match. |
| 150296 | SW-3 wrench for 10-inch Big Blue | Keep the housing length with the wrench number. |
| 144368 | SW-4 wrench for 20-inch Big Blue | The sheet lists this separately from the 10-inch wrench. |
These are manufacturer identification references. They do not establish fitment to another brand's housing or the contents and availability of a retail package. Opening a housing or replacing its seal requires the instructions for the exact equipment.
Source checked October 14, 2026. The revision identifies the sheet reviewed; no newer-revision claim is made.
GE GXWH04F, GXWH20S and GXWH40L housing references
Keep the complete GE model with the manual and diagram reference. The GXWH40L list uses different seal and wrench identifiers from the shared GXWH04F/GXWH20S list.
| Model in the source | O-ring reference | Canister wrench reference | Manufacturer locator |
|---|---|---|---|
| GXWH04F and GXWH20S | WS03X10038, item 003 | WX5X140, item 005 | GE 49-50202-2, 04-09 JR, printed page 5; both model columns list these references. |
| GXWH40L | HDRING, item 006 | HDWRNCH, item 007 | GE 49-50220-4, 12-12 GE, printed page 4. |
The GXWH40L list separately names HDHANDLE as the bypass handle at item 005 and WS30X10015 as the filter housing at item 010. An item number is a locator within its own drawing, not a universal part number: item 005 names the wrench in the shared GXWH04F/GXWH20S list and the handle in the GXWH40L list.
These dated manufacturer references identify components. They do not establish interchangeability with another GE model or a Pentair housing, retail package contents, or current orderability. Match the installed equipment to the applicable manual before selecting a part. Manufacturer sources checked October 15, 2026.
ENPRESS PIONEER: keep the E3-M housing and electronics references together
For equipment labeled ENPRESS PIONEER, retain the applicable manual and every suffix in the component number. These two ENPRESS manuals list different references:
| Parts-table entry | Metered-bypass manual, 01/2022 | PIONEER Pb / PIONEER As manual, 03/2025 |
|---|---|---|
| Item 1, manufacturer system/housing entry | ONE-E3-M Filtration System / Housing: CTA0840BBBKP5-06L00 | ONE E3-M Filtration System/Housing: CTA0840HBBKP0-06L00 |
| Item 4, meter assembly with cord | CT-METERASSY | CT-METERASSY-V2 |
| Item 10, umbrella containing non-Wi-Fi electronics | CT-PCBUMBRELLA-NONWIFI-V1; Version 1 | CT-PCBUMBRELLA-NONWIFI-V2; Version 2 |
| Separate board reference, not illustrated | CT-PCBBOARD-NONWIFI-V1; Version 1 | CT-PCBBOARD-NONWIFI-V2; Version 2 |
The item 1 codes retain the tables' system/housing description; they do not identify a loose replacement cartridge. Match the installed equipment and applicable documentation before selecting a component. The comparison does not establish interchangeability, a superseding part number or package contents.
Sources: ENPRESS metered-bypass manual, 01/2022, page 3 and PIONEER Pb / PIONEER As manual, 03/2025, page 3, parts tables. Dates are the editions printed on the back covers. Both are linked from ENPRESS's PIONEER page. Sources checked October 15, 2026; no latest-edition claim is made.
Related parts and help
Browse filter housings · Part references · Ask for fitment help
Sources reviewed
Review date: 2026-10-02. October 2026 supplier assortment records; Pentair Pentek Big Blue housing specification sheet. Manufacturer documentation controls technical claims and fitment.
Keep supplier wrench records separate
The current catalog has four distinct AFW supplier wrench records. These supplier SKUs are not verified aliases of the Pentair or GE manufacturer numbers above.
| Supplier SKU | Description retained in the offer |
|---|---|
| FHW-25 | For standard 2.5-inch filter housings; approximate wrench inside diameter 4 3/16 inches. |
| FHW-45 | Standard Big Blue label; approximate wrench inner/outer diameters 7.5/8.25 inches. |
| FHW-45-Pentek | Pentek Big Blue label; approximate wrench inner/outer diameters 6/6.75 inches. |
| FHW-45-PenCLR | Pentek clear-housing label; no wrench dimensions retained in this record. |
Keep the complete supplier SKU and installed housing model together. A shared 4.5-inch cartridge label does not establish that these tools are interchangeable. The supplier descriptions identify offers; they do not establish a tool match to a particular installed housing.
Water filter mounting bracket: bracket alone or bracket kit?
Keep the housing family, material and package designation together. Pentair's Big Blue / Big Black sheet 310053 Rev. F JA23, page 2 gives separate accessory numbers:
| Part number | Designation | Listed package distinction |
|---|---|---|
| 244718 | WB-ZP | Zinc-plated bracket only |
| 150061 | WB-ZP Kit | Zinc-plated bracket kit |
| 357639 | WB-SS | Stainless-steel bracket only |
| 357640 | WB-SS Kit | Stainless-steel bracket kit |
The word “kit” is part of the selection record, not permission to assume particular screws, anchors or other contents: this accessory table does not enumerate them. A bracket-only number should not silently become a kit number. This family reference also does not establish a universal bracket for every 10-inch or 20-inch housing, the suitability of a mounting surface or an installed load rating.
Source checked October 21, 2026. Confirm the exact housing, bracket and supplied package with the applicable manufacturer documentation. This comparison supplies no mounting procedure or WPS availability claim.
Hydronix HF5: a housing family, not an RO membrane
Hydronix lists reverse osmosis among the HF5 housing family's applications. That does not make HF5 a membrane element or a complete RO system. Its product table distinguishes these housing configurations:
| Complete reference | Listed configuration |
|---|---|
| HF5-10BLBK34PR | 10-inch cartridge length; blue body; black ribbed cap; 3/4-inch port; pressure-relief option. |
| HF5-10CLBK34PR | 10-inch cartridge length; clear body; black ribbed cap; 3/4-inch port; pressure-relief option. |
| HF5-20BLBK34PR | 20-inch cartridge length; blue body; black ribbed cap; 3/4-inch port; pressure-relief option. |
| HF5-ORING | Separate HF5 housing O-ring reference, not a cartridge or complete housing. |
The sheet's case quantities—12 for the listed 10-inch housings and 8 for the 20-inch versions—are manufacturer packaging fields, not a WPS selling unit. Length and appearance alone do not establish the correct cartridge, cap or seal for an installed assembly.
The manufacturer's webpage names HF5-10BLBK34PR beside its NSF/ANSI 42 materials-and-structural-integrity statement. That is not a contaminant-reduction claim or a verified current listing for every HF5 variant.
Sources checked October 21, 2026: Hydronix LIT-HF5-DS, June 18, 2025, and its HF5 manufacturer page. These are identification references; no current WPS offer, cross-family alias, installed fit or service procedure is established.
RO filter housing: prefilter canister or membrane vessel?
Identify which component the request concerns. The HF5 record above describes a cartridge-housing family with RO among its applications. A vessel containing the RO membrane is a different component. One named-system example shows why the housing, membrane, filter cartridge and seal need separate identifiers:
| Reference / part number | Item identified in this manual |
|---|---|
| 11 / 1000201 | Membrane housing with cap; membrane excluded |
| 12 / RO-TFC50 | Separate RO membrane |
| 16 / QCF-S | Quick-change sediment filter |
| 20 / RO-HOR | Membrane-housing O-ring |
Source: Sterling Water Treatment QCRO-50 / QCRO-50-PUMP / SRO-100 manual, QCRO-50 parts list, preserved by a distributor and checked October 21, 2026. No printed revision date was established; the archive-folder date is not presented as the publication date.
The shared QCRO wording does not extend these references to another manufacturer's system. Keep the full system and exact component record together; “housing” or a partial size alone does not establish replacements. This example does not identify the manufacturer of an otherwise unverified seller listing or establish its contents, compatibility, certification or availability. No opening, installation or repair procedure is supplied.
Hot-water sediment filters: check the housing and cartridge separately
A housing's length or color does not establish its hot-water suitability. Pentair's High Temperature Series sheet distinguishes these glass-reinforced nylon models:
| Housing reference | Port / nominal length | Published temperature range |
|---|---|---|
| 158319 | 1/2-inch NPT / #10 Slim Line | 40–160°F (4.4–71°C) |
| 150015 | 3/4-inch / #10 Standard | 40–165°F (4.4–74°C) |
| 150111 | 3/4-inch / #20 Standard | 40–165°F (4.4–74°C) |
The sheet separately lists a maximum pressure of 125 psi. Do not read separate maxima as proof that every combined temperature-and-pressure condition is acceptable. A housing reference does not establish a cartridge's temperature limit, sediment rating or reduction claim. The complete proposed assembly needs its own documented limits and suitability.
Source checked October 22, 2026: Pentair sheet 310054, Rev. E JE18, pages 1–2. The manufacturer currently links this dated sheet from its product page. No WPS package, availability, installed compatibility or installation procedure is established here.
Watts Big Bubba BBH-150: which cartridge sets the flow basis?
The same housing family accepts different cartridge types. Watts' ES-WQ-BBH sheet lists these separate maximum-flow entries:
| Cartridge type | Listed maximum flow |
|---|---|
| Pleated sediment | 150 GPM |
| Melt-blown sediment | 100 GPM |
| Pleated activated carbon | 15 GPM |
| Activated-carbon block | 4 GPM |
The sheet qualifies the pleated figure as highly dependent on micron rating, solids content and other factors. A housing headline therefore does not establish the flow or reduction performance of every cartridge installed inside it.
The housing table separately lists 125 psi maximum working pressure and a maximum temperature of 125°F at 80 psi. Do not combine the separate highest pressure and temperature into an unsupported simultaneous operating condition. Retain the exact housing, cartridge and applicable operating limits with the complete proposal.
Source: Watts ES-WQ-BBH, page 3, checked October 22, 2026. These are manufacturer specification fields, not installed measurements, a WPS package, current availability or an installation procedure.
VIQUA AWP40B-V: housing size, valve function and cartridge are separate fields
Identify the base housing before comparing a cartridge-inclusive kit. VIQUA's AWP40B-V product page provides these distinct fields:
| Field | Listed entry |
|---|---|
| Construction and valve description | Three-piece housing with pressure-relief valve. |
| Nominal cartridge format | 4.5 × 10 inches. |
| Housing dimensions | 8 × 15½ inches. |
| Connection | 1-inch FNPT. |
| Included accessories | WR40-50 wrench and BRHF bracket. |
The cartridge format is not the housing's outside size. The manufacturer separately places CMB-510-HF, a 5-micron cartridge, in its options list; the base housing description alone does not prove a cartridge-inclusive package.
Keep an additional kit suffix and its itemized contents on the order. The retailer's AWP40B-V-PS page names CMB-510-HF sediment filtration in its included-items list, but its short summary says carbon. Confirm that discrepancy rather than inferring a chlorine-reduction claim or two supplied cartridges.
Sources: VIQUA AWP40B-V and the outside retailer's -PS listing. No isolation-valve function, operating instructions, current certification, WPS offer or installed fit is established here.
