Water treatment equipment that depends on electricity

A house, filter housing, UV chamber, controller, and drinking tap shown as separate components.

If a power interruption leaves your water supply or treatment status uncertain, use known safe stored water and follow directions from your utility or local health authority. A tap may still dispense while an upstream treatment stage lacks power. Check each stage along the route serving that tap against its own documentation and service record. CDC emergency water guidance · WaterGroup GEN series and optional controls

Draw one line for each tap you rely on

Start at the water source, pass through the equipment in the order shown on your installer’s records, and end at the drinking tap. Make a second line for any tap that takes a different route. Copy the rows that exist in your setup.

Stage to look for Record for the installed equipment Question to resolve --- --- --- Supply pump or building booster Which fixtures it serves, exact model and responsible person Can the source deliver water while that pump is unpowered? Whole-house filtration or softener Housing, any powered valve or controller, and service contact Which treatment, control or scheduled service functions depend on power? UV chamber and controller Exact chamber model, lamp code and display location Who confirms operation after interruption? Automatic shutoff or other controlled valve Installed valve and the document that states its power-loss behavior Does this configuration stop or permit flow without power? Point-of-use RO Feed source, complete model, pump-equipped or no-pump version and served faucet What upstream stages and feed conditions does this branch need?

Read the map before deciding what a working tap tells you

Example: In one setup without a flow-stopping valve, municipal pressure feeds a sediment housing, then a GEN UV stage, then a kitchen tap. With the power out, the tap still flows and the UV controller is dark. Record “flow present” on the tap row and “UV operation unconfirmed” on the UV row. Use your stored safe water while resolving water-use guidance. If your unit has an automatic shutoff, have its documented behavior entered separately. CDC emergency water guidance · WaterGroup GEN series

Match spares to the installed stage during normal service

Use the system identification guide for label details or the UV lamp and sleeve identification guide when the chamber and controller carry different numbers. An installed Aqua Flo GEN H5-25 or GEN H6-25 that calls for the OEM 40040021 lamp matches the 40040021 listing. An installed Aqua Flo 475 PRO or 475BP PRO on a potable feed with an SED-10 sediment stage matches 65010086. Both matches are for documented service on existing equipment. GEN H5-25 manual, printed page 23 · Aqua Flo GEN H6-25 catalog row · 475 model and feed requirements · 475 manual, printed page 13

For more checklists and water outage guides, visit Emergency Water Prep.