Continuous drain flow can come from a valve that never returned to service, a stopped drive, foreign material, or an internal piston/seal leak. It is not proof that one seal kit fits every valve with the same symptom.
For a confirmed 5600SXT downflow softener, use the 5600SXT troubleshooting guide to record the display, cycle and any code before selecting a service part.
For the difference between an individual step and a complete recharge, see how long regeneration takes. Compare the observed start and documented return to service with the exact system's instructions; a cross-brand estimate does not establish a continuous-drain fault.
Why does a regenerating water softener need a drain?
Regeneration sends used backwash and rinse water away from the resin vessel through a valve discharge route. For the Fleck 5600SXT downflow example, Pentair's flow diagrams show service, backwash, brine/slow rinse, rapid rinse and brine-tank fill as separate positions. Drain flow observed during a documented regeneration step therefore needs a different assessment from flow that continues after return to service. Follow the illustrated service-and-regeneration example to see those selected routes.
Identify which connection is involved before describing “water from the softener”:
- Valve discharge: the route used for regeneration discharge.
- Salt-tank overflow: a separate connection for excess water if the salt tank overfills.
- Service outlet: the supply route toward household uses.
Morton's M20/M27/M30/M34/MC30 manual identifies the overflow as a gravity drain and explicitly keeps its hose separate from the valve-drain hose. A floor drain's presence alone does not establish that either route is suitable. Keep the model, applicable manual, discharge route, overflow provision and receiving drain with the installer's drain-planning record; receptor and site acceptance remain separate checks.
Sources checked October 20, 2026: Pentair 42684 REV L MY18, page 26; Morton 7388336 Rev. G, January 31, 2025, overflow-hose instructions. These examples explain the roles; they do not specify a universal drain size, approve a discharge destination or identify a failed part.
Diagnosis sequence
- Separate normal regeneration from a fault: record how long the drain has flowed and the displayed cycle.
- Confirm the valve reaches home/service: observe the documented cycle indicator and motor movement without forcing the cam or piston.
- Check drive and controller: a stopped timer motor, disconnected motor harness, or position-sensing fault can leave the valve in brine or backwash.
- Check the drain path: verify the line and flow-control configuration matches the system specification.
- Inspect internally only under the model manual: foreign material, piston damage, and seal wear require body-specific parts and depressurization.
Before following a component reference below, match the valve body and controller using the Fleck 5600 parts hub or the model and part identification route. A model match narrows the documentation to use; continuous drain flow alone does not identify a failed part.
Evidence examples
| Valve | Manual distinction | Relevant references |
|---|---|---|
| Fleck 5600 | Troubleshooting problem 11 lists foreign material, internal leak, a valve jammed in brine/backwash, and a stopped or jammed timer motor. | 13247 standard piston and 60125 seal/spacer kit only when the configuration matches. |
| Autotrol 255/263/268 | The cam indicator and controller show cycle position; drive, harness, cam, and optical sensor checks precede a parts conclusion. | 1235361 (exact identity unverified) and 1235373 sensor require body/controller confirmation. Resolve the supplied configuration for 1235361 before selecting a replacement. |
Record the label, cycle display, whether the motor is moving, and when the drain began before using the fitment form.
Service safety and limits
These checks identify a valve and narrow a parts search; they are not a substitute for the manufacturer service procedure. Before opening a valve, use the documented bypass procedure, isolate water, relieve pressure, and disconnect power. Water-treatment valve service should be performed by a qualified person. Stop if the label, flow direction, wiring, or part suffix does not match the cited manual.
Primary sources
- Pentair Fleck 5600 Service Manual, document 40106, troubleshooting problem 11.
- Pentair Autotrol 255/Performa Service Manual, document 3000440, cycle-indicator, drive, and troubleshooting sections.
Revision status: no superseding revision is asserted. Verify the revision block in the linked manufacturer document. Evidence reviewed September 28, 2026.
