Identifying replacement filters for a Microline TFC-335 or TFC-435? Match the complete system label and the manufacturer's parts list before comparing an offer. The two manuals below share several reference numbers, but the TFC-435 also lists a separate in-line post filter. A brand name or a membrane's stated daily capacity is not a complete compatibility check.
This is a document-based identification guide. It is not a stocked filter-kit listing, a compatibility guarantee for every equipment revision, or a replacement procedure.
Compare the documented parts lists
| Component | TFC-335, printed page 17 | TFC-435, printed page 17 |
|---|---|---|
| Sediment/carbon prefilter | S7028, callout 11 | S7028, callout 11 |
| RO membrane | S1229RS, 50 gpd, callout 12 | S1229RS, 50 gpd, callout 12 |
| Activated carbon post filter | S7025, callout 19 | S7025, callout 18 |
| Separate in-line activated carbon post filter | No corresponding entry in this parts list | S7206W-JG, callout 22 |
Sources: Microline TFC-335, Form S1299-09, January 17, 2018 and Microline TFC-435, Form S1299-07, January 17, 2018. These dates identify the documents compared; they do not claim the newest revision or cover undocumented modifications.
Before comparing a replacement offer
- Record the complete system model and the manual matching its revision.
- Keep the existing filter or membrane's complete identifier, including its suffix.
- Compare each offered component with the relevant drawing callout. Do not assume “filter kit” includes the membrane or the extra in-line stage.
- Resolve an offered number that differs from the manual before buying. Neither table establishes another membrane as an equivalent merely because its brand or appearance is similar.
Keep identification separate from maintenance
For the information to record about an RO membrane, use our RO membrane identification guide. For an ongoing service record, see RO filter and membrane maintenance. Replacement, sanitation and pressure-related work need the applicable system instructions and a qualified service provider.
Ask for identification help with the system model, full component number and the offer you are comparing. Availability, supplier authorization and package contents must be confirmed separately; this page does not offer these components for sale.
Prepared by Water Parts Supply. Manufacturer parts lists checked October 14, 2026.
TFC-335 membrane production and system production are different ratings
The 50 GPD membrane identifier in the parts list above is not the TFC-335's complete-system production rating. Table A on printed page 5 of Microline manual S1299-09, January 17, 2018, gives two separately qualified production entries:
| Entry | Published production | Reported test basis |
|---|---|---|
| Membrane production | 41–53 GPD | No product-water backpressure; 65 psig, 77°F / 25°C and 250 ppm TDS; a new membrane after the manual's 24-hour conditioning. |
| System production | 12 GPD | 50 psig, 77 ± 2°F and 750 ± 40 mg/L TDS, using the manual's stated system-test method. |
These figures describe different tests, not a promise of output at a particular home. Keep the membrane reference, complete system and test conditions together when comparing a claim. The difference between the two flow figures is not itself an efficiency rating.
This historical TFC-335 reference does not assign the same production to a TFC-435, TFC-400 or modified system, establish current certification or supply pressure-adjustment instructions. Confirm the applicable model and document before interpreting an installed result.
TFC-400: use its separate parts document and retain the membrane-number difference
ESP's TFC-400 resource list links a model-specific manual, Form S1462-04, November 10, 2015. Printed page 19 separates these component references:
| Drawing item | Component | Part number |
|---|---|---|
| 11 | Sediment prefilter | S7011 |
| 12 | Activated-carbon prefilter | S7028 |
| 16 | RO membrane, labelled 50 GPD | S1764RS |
| 19 | In-line activated-carbon postfilter | S7206W-JG |
Keep the conflicting reference visible: the current ESP TFC-400 replacement page instead lists S1229RS for the membrane. The shared 50 GPD label does not resolve that difference. Neither reference alone establishes a supersession or interchangeability between S1764RS and S1229RS.
Retain the complete installed model, applicable revision and proposed supplied part when resolving the match. Do not transfer the TFC-335/TFC-435 parts table above to a TFC-400 merely because some numbers repeat. Sources checked October 21, 2026; no current WPS offer, package contents, output guarantee or replacement procedure is established.
Microline S1276: check valve or separate retainer?
The TFC-335 manual lists the check valve and its retainer as different components. Preserve the part number as well as the drawing callout:
| Drawing number | Part number | Manufacturer description |
|---|---|---|
| 9 | S1276 | Check valve |
| 10 | S1277 | Check valve retainer |
The same parts table separately describes manifold assemblies with and without a monitor. An individual valve, its retainer and a complete manifold are different order scopes; the name of one does not state a seller's supplied package.
Source: Microline TFC-335 manual S1299-09, printed page 17, dated January 17, 2018 on its final page; checked October 22, 2026. Match the installed model and applicable edition before selecting a part. These references do not establish a port dimension, current supersession, universal Microline fit or WPS availability, and supply no removal, repair or replacement procedure.