RO Membrane Identification Guide

Use the membrane or system label first. Similar nominal output wording does not establish membrane dimensions, connection configuration, chemistry, or system compatibility.

In this guide: RO basics · TFC · RO / DI / remineralization · rejection / recovery · GPD rating comparison · SW30-4021 · LC LE PRO-4040 · GE FQ18MN / FQ18PN / FQ18RT. · Cleaning versus crossflow

What is reverse osmosis?

RO stands for reverse osmosis: a process in which applied pressure moves water through a semipermeable membrane. “RO water” refers to the water produced by that process, identified as permeate in the stream record below. A complete RO system may include other filter stages; the membrane is one component of that system.

The EPA point-of-use RO overview explains the pressure-driven membrane process. This definition does not identify a brand, cartridge format, compatible replacement or a particular contaminant-reduction claim. Use the complete system and component identifiers with the records below.

Why is it called reverse osmosis?

Reverse osmosis reverses the direction of water movement associated with ordinary osmosis. DuPont's explanation compares two solutions separated by a semipermeable membrane:

Net water direction in the manufacturer's simplified comparison
Process Water movement across the membrane Driving condition
Ordinary osmosis From the more dilute solution toward the more concentrated solution The difference in dissolved-substance concentration drives net movement until an opposing pressure balances it.
Reverse osmosis From the more concentrated side toward the dilute product-water side Applied pressure overcomes the osmotic pressure and drives water in the opposite direction.

“Dilute” and “concentrated” describe dissolved-substance concentration in this comparison. For the names of the actual RO streams, use the feed, permeate and concentrate record. An operating pressure or a particular membrane's reduction performance requires that system's own documented conditions.

Source: DuPont, Reverse Osmosis, “Overcoming osmotic pressure”, checked October 21, 2026; no webpage revision date displayed.

What does TFC mean on an RO membrane?

TFC means thin-film composite. DuPont illustrates its FilmTec membrane construction with a polyamide barrier layer, a microporous polysulfone interlayer and a polyester support web. Keep this material description alongside the complete element number when comparing replacements.

Record the dimensions and specified rating conditions separately in the element format and rating record. The exact element reference and system documentation establish the replacement selection.

Source: DuPont FilmTec Technical Manual, 45-D01504-en, Rev. 20, August 2026, section 1.4, printed page 17, and glossary, printed page 178. Checked October 19, 2026.

RO membrane pore size: what does a micron figure tell you?

A commonly quoted RO figure is 0.0001 micron. APEC uses that number in its educational RO filtration comparison. Treat it as that source's description of the process, rather than a complete replacement specification for every membrane.

DuPont's FilmTec manual describes membrane performance through permeate flow and salt rejection, with pressure, temperature, recovery and feed concentration affecting the result. Its explanation uses a solution-diffusion model. That is a different specification record from a sediment cartridge's nominal or absolute particle-size statement.

Keep the rating basis with the component
Component being compared Evidence to retain
Sediment cartridge Complete part number, micron value, nominal/absolute qualifier and any stated efficiency or test basis.
RO membrane element Complete designation, documented format, flow and rejection figures, and the product sheet's test conditions.

Use the element format and rating record for a membrane comparison and the micron-rating guide for a particle filter. A micron figure alone establishes neither a compatible replacement nor a complete system's reduction claims. Source: DuPont 45-D01504-en, Rev. 20, August 2026, printed pages 15–16; APEC FAQ checked October 19, 2026.

RO membrane, DI polishing or remineralization: what job does each stage do?

A membrane, a deionization stage and a mineral-adding cartridge have different jobs. Identify the intended application before treating a downstream cartridge as an upgrade or replacement for another stage. “Inline” describes a component format; “post-filter” describes a position. Neither supplies the treatment function.

Three roles to distinguish in the exact system's documentation
Stage or component Documented role to establish Owner decision
RO membrane The pressure-driven membrane process described above; retain its separate feed, permeate and concentrate record. Identify the membrane and its applicable rating conditions separately from downstream cartridges.
DI polishing A deionization stage in the named RO/DI system, with its own cartridge and monitoring requirements. Confirm the intended use and exact DI configuration; a final reading also reflects treatment after the membrane.
Remineralization / pH stage A mineral-adding function documented for the exact cartridge, rather than DI polishing. Record what medium is added and why the system calls for it; do not choose it solely to pursue the lowest TDS display.

Worked reading: separate the membrane from the DI stages

SpectraPure's MaxCap Manual Flush manual, dated October 1, 2019, covers MC-RODI-90-10-MF and MC-RODI-180-10-MF. It describes an RO membrane followed by MaxCap and SilicaBuster DI stages. For an identification record using the named 90 model, retain the membrane separately from DI-MC-10HC and DI-SB-10HC; these are the manual's component references.

Pages 6 and 8 distinguish four monitored locations: incoming tap water, RO water before DI, water after MaxCap DI, and final water after SilicaBuster DI. That gives the owner a useful question before reporting a number: which documented stage does this reading describe? The final DI reading is not the membrane-only reading. Use existing labels and normal owner-accessible displays; this comparison requires no probe relocation or plumbing work. This dated example does not establish another system's sequence, cartridges or drinking-water suitability.

Worked contrast: a cartridge that adds calcium carbonate

APEC's FI-PHPLUS-QC manufacturer page identifies a calcium-carbonate remineralization cartridge and describes adding that mineral to raise pH. That is a different documented objective from the MaxCap example's DI polishing. It does not establish a particular outlet pH, a mineral dose, a health benefit or interchangeability between the examples.

Before comparing parts, keep the intended use, complete system and manual edition, exact component and medium, stage position, and documented monitoring or service requirement together. Leave an undocumented position or fit unresolved. Use the existing RO stage and maintenance record for RCC7AK and ROES-PH75 replacement references and the separate sampling question. Follow the applicable system instructions rather than adding, bypassing or rearranging stages from this comparison.

Sources checked October 17, 2026: SpectraPure manual cover and printed pages 3, 5–6 and 8; APEC FI-PHPLUS-QC page, no revision displayed. These are component/function examples, not current Water Parts Supply offers, universal stage order, certification or treatment-performance guarantees.

Why does RO send water to the drain, and what does the ratio mean?

RO separates incoming water into treated water and a concentrate stream. The concentrate carries material that did not pass through the membrane and is normally directed to the drain in a point-of-use system. A drain stream is part of the process; its presence alone does not identify a failed part.

Read the order of a ratio before comparing systems. 3:1 waste-to-treated means three units sent to drain for each unit produced for use. A claim written 3:1 treated-to-waste means the reverse. “1:1” without named streams and test conditions leaves the comparison incomplete.

EPA's current WaterSense product search explains efficiency as the share of incoming water available to the user as treated water. Its 30% example means 30 gallons treated from 100 gallons entering, with 70 gallons sent to drain: about 2.33:1 waste-to-treated. This arithmetic explains the metric; it is not a measured result or recommended setting for your system.

Keep an efficiency rating separate from a membrane recovery rating. EPA's November 2024 supporting statement explains that storage-tank back pressure can make a tank-equipped system's operating efficiency lower than its tank-bypassed recovery figure. Compare the complete model, stated metric, test conditions and whether automatic flushing is included. A membrane GPD label describes production, not the waste ratio.

Sources: EPA WaterSense product-search efficiency explanation; supporting statement, Version 1.0, November 2024, printed pages 5–6. Checked October 15, 2026. No WPS product's efficiency or WaterSense status is asserted. Do not change a restrictor, tank or pump to pursue a ratio without the applicable manufacturer's instructions.

What is TDS creep, and why can the first RO reading after idle time be higher?

TDS creep describes an increase in dissolved-solids concentration on the RO product-water side during idle or reduced-production conditions. In the Water Quality Association's tank-equipped point-of-use example, ions continue diffusing through the membrane after the tank is full and feed flow stops. The first draw after that idle period can therefore have a higher TDS concentration than a sample taken during production.

A 2022 study of RO water purifiers also examined the higher initial permeate TDS associated with repeated running and resting, including the effects of resting time and feed concentration. This process explanation is different from identifying the meter's display units or diagnosing an individual membrane.

Keep the sampling conditions with an RO TDS comparison
Record field Distinction to preserve
Operating state First draw after idle time versus a reading during the system's documented production/testing condition.
Sample location Membrane product water, storage tank or final faucet; record any later DI or remineralization stage separately.
Measurement Meter model, unit, temperature and conversion basis; keep feed-water and product-water results distinct.

A TDS reading does not identify a specific contaminant or select a replacement part. Use the exact system's instructions for testing or flushing; this explanation establishes no universal flushing time, discard volume, safe TDS value or membrane-replacement threshold. The TDS and conductivity record helps retain the measurement basis.

Sources: Water Quality Association, POU Reverse Osmosis Performance and Sizing, ©2013, page 3; Kang and Yun, Membrane Journal 32(2), 126–132, 2022, abstract. Sources checked October 20, 2026; study-specific mitigation procedures are not reproduced.

Identification checklist

  1. Record the complete printed membrane or system number.
  2. Record only documented membrane size and connection information.
  3. Check the applicable system manual before treating a replacement number as compatible.
  4. Keep stated package quantity separate from the membrane identity.

For a labeled Microline TFC-335 or TFC-435, compare the model-specific filter and membrane parts lists, including the separate in-line stage listed for the TFC-435.

Record whether the membrane is new dry, new preserved or previously used

Keep the complete membrane model, documented shipping condition and whether it has ever been wetted or installed together. “New” alone leaves the storage state unclear.

FilmTec storage-state distinctions in DuPont 45-D03716-en Rev. 11, February 2026, pages 1–2
Documented state What the named manufacturer example establishes
New dry FilmTec element DuPont says no preservation solution is required and the element should remain in its sealed bag until use.
New wet/preserved FilmTec element DuPont describes this supplied state separately. The dry-element branch does not describe these elements.
Previously used FilmTec element DuPont gives separate preservation instructions for used elements removed from a vessel and warns that drying after use may permanently reduce water permeability.

Retain the packaging, storage history and applicable instructions for the exact model. If its state or history is unknown, ask the manufacturer or supplier before treating it as usable; appearance alone does not resolve that record. These FilmTec examples provide no preservation, rewetting, shutdown or restart procedure and do not transfer instructions to another membrane brand.

What does RO membrane preservative identify?

In DuPont's named wet-shipped FilmTec example, the storage solution contains sodium metabisulfite (SMBS). The manufacturer describes its role as preventing biological growth during storage and shipping. This is a supplied-state reference, not a universal membrane cleaner or a reason to add a chemical to an installed drinking-water system.

The same DuPont excerpt, Rev. 11, February 2026, page 1, treats new dry elements separately and says they require no preservation solution. Record the exact membrane, packaging label and documented shipped state before asking about a preservative. A generic SMBS name does not specify a suitable purchased formulation, grade or procedure for another element. Source rechecked October 20, 2026 (America/Chicago); no mixing, dosing, cleaning, shutdown or restart instructions are supplied here.

Does a 12-month storage checkpoint mean the membrane expires then?

DuPont's inspection checkpoints are not labelled as a universal membrane expiration date. Read the stated shipping or preservation condition before applying a date to a stored element. The same excerpt gives different checkpoints for different states:

  • New preserved FilmTec elements: page 1 calls for a condition inspection 12 months after shipment and every three months thereafter.
  • Re-preserved elements: page 2 gives a separate three-month inspection interval.
  • New dry elements: page 1 treats these as a separate supplied state, without a preservation solution; that does not describe an element that dried after use.

A checkpoint is not proof that an element is usable until that date or unusable immediately afterward. It also does not turn an unknown shipping condition into a confirmed dry or preserved one. This excerpt does not supply one shelf-life figure for every RO membrane brand and storage history.

For a stored replacement enquiry, retain the complete element designation, documented supplied state, shipment date, original packaging record and known storage history. Ask the supplier or manufacturer to resolve missing dates and the applicable condition record. A purchase or receipt date alone does not establish when the manufacturer's shipment-based checkpoint began.

Source: DuPont 45-D03716-en Rev. 11, February 2026, pages 1–2. These are document-reading distinctions, not a usability assessment, inspection method, preservation recipe, rewetting procedure or restart instruction.

Source: DuPont, Handling, Preservation and Storage, 45-D03716-en Rev. 11, February 2026, pages 1–2. Source checked October 16, 2026. This is a storage-state record, not a usability assessment or current package statement.

How the membrane works: keep feed, permeate and concentrate separate

A membrane element and its housing are different components, and the water streams around the membrane have different names. DuPont's FilmTec technical manual, 45-D01504-en Rev. 20, August 2026, page 15, Figure 5, illustrates a crossflow process: feed enters the membrane system, part passes through the membrane as permeate, and the remaining concentrate leaves through a separate stream.

Manufacturer diagram terms for a membrane buying or service record
Source term What the term identifies What to keep with the label
Feed Water introduced to the membrane element or system. Exact system and documented feed connection; any existing reading with its location, units and conditions.
Permeate Water that passes through the membrane into the product-water stream. Documented permeate connection and any component or sample-point number.
Concentrate / reject The non-permeated stream leaving the membrane element or system. Documented concentrate connection and the exact separate component being identified.

In the FilmTec spiral-wound element described in section 1.7, page 20, feed/concentrate channels and the product-water tube are distinct paths. The manual separately describes the membrane element inside a pressure vessel. Keep an element, vessel, connector, seal and flow-related accessory on separate lines of a parts request rather than treating “RO membrane” as the name of the whole assembly.

These diagram terms explain component and stream identity. They do not identify a particular installed port by tubing color, prescribe an operating pressure or recovery setting, select a replacement from a slow-flow symptom, or establish drinking-water safety. Use the complete element designation, applicable system drawing and the format/rating record below for the actual comparison. For an installed tank-equipped system's changed delivery, use the production, storage and delivery observation record.

Source scope: DuPont FilmTec manual 45-D01504-en Rev. 20, pages 15 and 20; reviewed from the saved August 2026 manufacturer document. The terminology is not a performance test, universal connection layout or retailer package statement.

RO rejection versus recovery: what does each percentage measure?

Rejection describes a reduction in dissolved-substance concentration; recovery describes the share of feedwater that becomes permeate. A salt-rejection percentage does not tell you the volume sent to the drain.

As an arithmetic example, 98% rejection corresponds to 2% passage on the same concentration basis. That does not mean 2% of the water goes to drain, and it is not a measured rating for your membrane. Keep the named substance, complete model and source test conditions with a rejection figure. Pressure, temperature, recovery and feedwater salt concentration can affect membrane performance.

Source: DuPont FilmTec technical manual, 45-D01504-en Rev. 20, August 2026, page 15. These terms help interpret a specification; they do not establish drinking-water safety, a replacement threshold or compatibility with an installed system.

Keep element format and rating conditions in separate fields

Record the full RO element designation rather than choosing from “1812,” “4040” or a GPD figure alone. DuPont's FilmTec technical manual, 45-D01504-en Rev. 20, August 2026, section 1.8, page 21, distinguishes membrane type and element size in its nomenclature. Its page 23 performance discussion and Table 4 state that performance belongs with the product data sheet and its test conditions.

Record field Copy from the exact label or source
Identity Manufacturer; complete element designation and suffix; installed system/model: ____
Format Documented diameter, length, units and dimensional-drawing reference: ____
Connection Documented end/connection configuration and applicable system manual: ____
Rating Stated flow value and units; exact product-data-sheet revision: ____
Rating conditions Source's feedwater, temperature, test pressure, pH and recovery conditions: ____
System allowance Replacement designation explicitly supported by the system documentation / unresolved match: ____

Mark missing information unknown. DuPont nomenclature and test conditions do not establish a Puret replacement or compatibility with another system. A larger stated flow is not permission to upgrade an installed membrane.

Manufacturer source checked October 14, 2026. This is a documentation record, not a performance test or replacement procedure.

For a nanofiltration-labeled NF90-4040 or NF270-4040, use the nanofiltration element and coupler guide to compare the exact NF identity and the separate coupler requirement.

Worked comparison: keep GPD with the membrane's test feed

GPD means gallons per day. These FilmTec sheets give permeate-flow values under stated test conditions, rather than promised faucet delivery or daily output in an installed system. All three examples below use 50 psig (3.4 bar), 77°F (25°C) and 15% test recovery. Their feed specifications differ.

Selected page 1 properties and rating notes from the three named DuPont sheets; rounded units retained
Rating field TW30-1812-50HR BW60-1812-75 TW30-1812-100HR
Published permeate flow 50 GPD (7.9 L/h) 75 GPD (12 L/h) 100 GPD (15.8 L/h)
Test feed 500 ppm NaHCO₃ (sodium bicarbonate) 250 ppm softened tap water 250 ppm softened tap water
Test pH 8.0 Not stated in the rating note Not stated in the rating note
Typical stabilized salt rejection 99% 99% 98%
Minimum salt rejection 98.0% 96.0% 96.0%
Stated individual-element flow variation +25% / −15% ±20% ±20%

Read the differences: matching pressure, temperature and recovery do not make these identical tests. Keep sodium bicarbonate separate from softened tap water, and do not replace either description with an unqualified “TDS” figure. The notes do not report every constituent of the softened tap water or supply its test pH; an operating pH limit elsewhere in a sheet does not fill that blank.

Compare typical stabilized rejection with typical stabilized rejection; minimum rejection is a separate value. The largest GPD figure does not carry the highest typical rejection here. This is a comparison of published specifications, not a ranking for your water conditions. The stated element variation is not an installed-output forecast or permission to change system pressure.

The 15% figure is test recovery, separate from salt rejection; it does not establish a complete system's efficiency or waste ratio. Confirm the installed system's documented replacement before selecting an element. These rows establish no upgrade compatibility, supersession, current certification, Water Parts Supply package or drinking-water-safety conclusion. For service questions, use the RO stage and maintenance record.

Sources, page 1 table and notes 1–3: TW30-1812-50HR, 45-D01750-en Rev. 5, January 2021; BW60-1812-75, 45-D01705-en Rev. 7, December 2022; TW30-1812-100HR, 45-D01697-en Rev. 8, December 2022. Checked October 16, 2026; no newest-edition claim is made.

Why temperature can change RO production and salt rejection differently

A 50 GPD rating describes production under the element's stated test conditions. It does not mean that a change in production measures the same thing as a change in salt rejection. DuPont's Factors Affecting RO Membrane Performance, under “Effect of temperature,” explains that warmer feed increases water diffusion through the membrane and therefore water flux. Salt diffusion also increases, which can increase salt passage and lower rejection.

These are two separate results: more permeate does not by itself demonstrate better salt rejection. Keep the test temperature with both the production and rejection figures when comparing the documented 50 GPD element above. This manufacturer explanation supplies no installed-output prediction, heating instruction or replacement compatibility claim. Source text checked October 20, 2026.

SW30-4021: distinguish the element length before ordering

Keep SW30-4021 intact when comparing a seawater RO element. DuPont's Seawater Elements data sheet, 45-D01519-en Rev. 10, October 2024, page 1, gives SW30-4021 and SW30-4040 separate product rows. They share the drawing's B dimension but have different A lengths.

Exact manufacturer model rows, drawing dimensions and order identity
Element designation Manufacturer part number Drawing A: length Drawing B: diameter Catalog comparison
SW30-4021 80740 21.0 in (533 mm) 3.9 in (99 mm) 703080740 — SW30-4021 element; listed customer unit: single.
SW30-4040 12082966 40.0 in (1,016 mm) 3.9 in (99 mm) Manufacturer reference row; compare any offer by its own complete designation.

The manufacturer part number and retailer catalog identifier are separate fields. The linked listing states SW30-4021; it does not turn another SW30 or PRO designation into that model. Use the full dimensional drawing and the installed vessel/system documentation for the end connection and allowed replacement. A matching diameter alone does not complete that check.

For the order record, retain the installed element label, exact allowed replacement designation, data-sheet revision and drawing reference, full catalog identifier, listed customer unit and separately confirmed package contents. This identifies the comparison; it does not specify desalination operating pressure, establish system fit or promise production.

Exact manufacturer rows and linked catalog identity checked October 15, 2026. Source dimensions come from the OEM drawing, independently of supplier description wording.

LC LE PRO-4040: record the complete element and separate coupler

Keep LC LE PRO-4040 intact when comparing an element label with an offer. DuPont's product data sheet, 45-D01670-en Rev. 13, June 2026, page 1, supplies the following exact identity and drawing fields.

Manufacturer fields for the LC LE PRO-4040 comparison record
Field Exact manufacturer record
Complete model FilmTec LC LE PRO-4040 element
Manufacturer part number 12081512
Drawing A 40.0 inches (1,016 mm)
Drawing B 3.9 inches (99 mm)

The drawing separately identifies FilmTec coupler 89055, ordered separately for each element. It states that each coupler includes two 2-210 EPR O-rings, part 89255. Keep the element, coupler and O-ring references on separate lines of the buying record. This manufacturer ordering note does not establish the shipped contents of a retailer's element package.

The 7030404008 catalog record states “DuPont FilmTec LC LE PRO 4040 RO Membrane” and a customer unit of single. Retain retailer and manufacturer identifiers separately when comparing package contents.

A label or request reading only “LCLE-4040” leaves the PRO designation unresolved; these sources do not establish an old-to-current replacement relationship. Use the full installed label and applicable vessel/system documentation. These fields do not establish interchangeability or treatment performance.

GE FQ18MN: separate the membrane from the prefilter/postfilter set

For a GE reverse-osmosis replacement membrane request, retain the complete FQ18MN number and the installed system model. GE's official FQ18MN record identifies a membrane cartridge and explicitly lists GXRV40TBN, GXRQ18NBN and GNRQ18NBN as compatible systems.

The GE owner's manual, 49-6000224 Rev. 1, January 2025, printed page 35, separates these references under GNRQ18NBN 00 and GXRQ18NBN 00:

Exact reference Component in the parts catalog
FQ18MN, item 0003 RO cartridge
FQ18PN, item 0002 Pre and post filter cartridge set

Keep the two numbers on separate lines of the parts request. FQ18MN identifies the membrane; it does not identify the separate FQ18PN filter set. Record the complete system suffix and applicable manual alongside the cartridge label. These GE references do not establish a replacement for another brand or the contents of a retailer's package.

FQ18RT is a separate stage reference. GE's FQ18RT manufacturer record identifies its remineralization/antimicrobial replacement filter and lists GXRV40TBN, GXRQ18NBN and GNRQ18NBN. This web record is separate from the manual table above. Keep FQ18RT, FQ18MN and FQ18PN as distinct component records; a matching system name does not make their jobs or supplied quantities equivalent. Confirm the complete installed model and stage before comparing an offer.

What does an RO membrane cost? Compare the exact offer and unit

The following Water Parts Supply membrane offers were checked on October 20, 2026 (America/Chicago). Each is listed as a single membrane element, with prices in USD.

Dated prices for three individual offers, not a market-wide average
Catalog offer Supplier-listed membrane model Price for one element
60181250 FilmTec TW30-1812-50HR $38.87
60181275 FilmTec BW60-1812-75 $41.03
601812100 FilmTec TW30-1812-100HR $47.51

Compare price only after confirming the complete required model, element format and applicable system documentation. These are different membrane identities; a lower price or larger GPD label does not establish a suitable substitute. Keep the rating conditions and format record with that comparison.

A single-element price does not include a housing, prefilter set, postfilter or service work unless the particular offer expressly says so. For a broader maintenance estimate, use the itemized RO replacement-cost example and keep parts, quantities and other charges separate.

Check the linked product page and final order total for current pricing and supplied contents. These dated examples do not establish stock, compatibility, a membrane-replacement schedule or an installed-service price.

RO membrane cleaning: which activity does the service record mean?

Normal rinse-water flow during filtration and a dedicated membrane-cleaning service are different activities. APEC's membrane-maintenance FAQ describes crossflow and rinse water normally directed to the drain. That operating description does not document that a separate cleaning service has been performed.

DuPont's Cleaning Procedures for FilmTec Elements, Form 45-D01696-en, Rev. 13, February 2026, addresses chemical cleaning and dedicated cleaning equipment. Its page 2 also notes that pretreatment, pressure-control or recovery problems can affect output or salt passage without the elements necessarily requiring cleaning. This technical reference is not a cleaning authorization for an unidentified residential system.

Before comparing cleaning with replacement, record the complete system and membrane model, applicable manufacturer's document, observed change and exact task proposed. Keep a system-sanitization record, a membrane-cleaning record and a membrane-replacement record distinct; a general “RO serviced” note leaves those component questions unanswered.

Use the model and stage record to retain that evidence. This distinction supplies no chemical recipe, operating adjustment, cleaning threshold or replacement interval. The exact system's approved service scope remains the starting point.

Example part identifiers

These examples identify documented parts, not universal fitment.

  • 60181250 — 60181250 DuPont/Dow FilmTec TW30-1812-50HR TFC RO Membrane - 50 GPD
  • 601812100 — 601812100 DuPont/Dow FilmTec TW30-1812-100HR TFC RO Membrane - 100 GPD
  • 60181275 — 60181275 DuPont/Dow FilmTec BW60-1812-75 TFC RO Membrane - 75 GPD (Replaces TW30-1812-75)

For an installed RO system, use the filter and membrane service record to organize maintenance by stage. If water delivery has changed, the RO low-flow observation worksheet separates production, storage and delivery questions before a service review.

For a pump identified in the system documentation, use the Aquatec delivery and booster pump identification guide to record the complete role and model code separately from the membrane and any listed accessories.

AXEON HF1-2521: match 200375 and its rating conditions

The Water Parts Supply 200375 listing identifies a single AXEON HF1-2521 membrane element, with the supplier description 2.5 × 21, 400 GPD, 150 PSI. AXEON's HF1-Series specification MKT-572-C, dated May 28, 2026 independently pairs part number 200375 with HF1-2521. This is an element reference, separate from a housing or complete RO system.

HF1-2521 manufacturer rating fields, not installed-system promises
Field AXEON specification
Applied pressure for the published flow 150 psi / 10.34 bar
Permeate flow 400 GPD / 1.51 m³/day
Nominal salt rejection 99%; minimum 96% is stated separately

The sheet's warranty-evaluation conditions are 550 ppm filtered, dechlorinated municipal tap water, 77°F / 25°C, 15% recovery and the specified pressure. It allows ±20% permeate-flow variation for warranty evaluation. Keep that qualification with the rating; 400 GPD is not a guaranteed delivered volume in your installation.

The source's maximum operating pressure is a different field from the 150 psi rating condition. Neither supplies a pressure-setting instruction. Match the exact system's documented replacement and element connections before ordering; shared nominal dimensions or another brand's similar GPD figure do not establish interchangeability. Manufacturer sheet and WPS listing checked October 20, 2026.

Related parts and help

Browse ro membranes · Part references · Ask for fitment help

Sources reviewed

Initial source review: 2026-10-02. See individual sections for additional source-check dates and document editions. Published by Water Parts Supply. October 2026 supplier assortment records; DuPont FilmTec reverse-osmosis and nanofiltration technical manual. Manufacturer documentation controls technical claims and fitment.

Pureteck TFCK-1812-50 and -100: check the component listing's scope

NSF's Pureteck Co., Inc. entry names TFCK-1812-50 and TFCK-1812-100 under “Components: RO Membrane.” Record the complete code; these are separate listed component identifiers.

The entry qualifies its Standard 58 certification as material requirements only. That scope does not establish a particular contaminant-reduction result, installed-system certification or interchangeability with another membrane. Read the listing's footnotes and applicable conditions in the original record before relying on it.

Open NSF's exact Pureteck listing, directly checked October 21, 2026; its displayed status date was October 21, 2026. Use the model, standard and claim workflow to distinguish a component record from the complete system's claim. This reference supplies no WPS offer, replacement fit, flow promise or servicing procedure.

Hydranautics membranes: distinguish ESPA1-LD-4040 from ESPA1

A shared ESPA name does not make two membrane elements equivalent. These Hydranautics product sheets list different flow and active-area fields:

Manufacturer-listed comparison fields; retain each complete model
Model Specified permeate flow Active area, identified as indicative
ESPA1-LD-4040 2,450 GPD 80 square feet
ESPA1 12,000 GPD 400 square feet

Both sheets state a 1,500 ppm sodium-chloride test solution, 150 psig applied pressure, 77°F / 25°C, 15% permeate recovery and pH 6.5–7.0. Keep those conditions with the flow figures. Their individual-element flow allowances differ: ±15% for ESPA1-LD-4040, compared with +25% / −15% for ESPA1.

These are manufacturer rating comparisons, not pressure-setting instructions or promised installed output. The sheets mark their general-description values, including active area, as indicative. Check the exact system's element requirements and the complete manufacturer record before selecting a replacement; neither the brand nor a larger GPD figure establishes fit.

Sources checked October 21, 2026: Hydranautics ESPA1-LD-4040 data sheet, dated August 22, 2024; ESPA1 data sheet, dated July 17, 2025. These document examples establish no current WPS offer or compatibility with another brand.

2.5 × 40 RO membranes: the format does not choose the model

Two FilmTec examples show why a nominal 2.5-inch vessel size and 40-inch length are insufficient replacement identifiers. DuPont documents TW30 PRO-2540 and SW30-2540 separately, with different constructions and rating conditions.

Exact model comparison from the two manufacturer sheets, page 1
Documented field TW30 PRO-2540 SW30-2540
Manufacturer part number 12081019 12082989
Element drawing length / diameter 40.0 / 2.4 inches (1,016 / 61 mm) 40.0 / 2.4 inches (1,016 / 61 mm)
Outer construction Tape wrap Fiberglass wrap
Published permeate flow 1,000 GPD 700 GPD
Test feed / applied pressure 2,000 ppm NaCl / 225 psi 32,000 ppm NaCl / 800 psig
Test temperature / recovery 77°F (25°C) / 15% 77°F (25°C) / 8%

The drawing's 2.4-inch element diameter and the nominal 2.5-inch vessel designation describe different fields. Matching those dimensions does not make these models interchangeable. Their GPD values were obtained with different feed concentrations, pressures and recoveries; they are not a same-condition comparison or operating settings for your system.

The WPS TW30-PRO-2540 listing and 703080737 / SW30-2540 listing identify single membrane elements. The retailer identifier 703080737 is separate from DuPont's 12082989. Confirm the installed system's allowed complete replacement and the supplied package before selection; neither listing establishes a vessel, complete system, present stock or an upgrade.

Sources checked October 21, 2026: TW30 PRO sheet, 45-D03971-en Rev. 5, October 2024; SW30 seawater sheet, 45-D01519-en Rev. 10, October 2024. No compatibility, installed-output, certification or treatment guarantee is inferred.

2.5 × 40 membrane example: keep the HF1-2540 document with its rating

AXEON identifies HF1-2540 as part 200376. Two manufacturer documents publish different permeate-flow figures for that same named element:

Source-specific HF1-2540 rating records
AXEON document Published flow Applied pressure in its table
Membrane catalog, HF1-Series table 850 GPD 150 psi
HF1 specification MKT-572-C, May 28, 2026 1,000 GPD 150 psi

The May 2026 sheet's drawing gives a 40-inch length and 2.40-inch element diameter, separately from the nominal 2.5-inch housing designation. Its warranty-evaluation basis is 550 ppm filtered, dechlorinated municipal feed, 77°F/25°C and 15% recovery, with flow variation of ±20% allowed for warranty evaluation.

Retain the complete model, part number and applicable document when asking about a proposed element. The different published figures do not by themselves establish a physical redesign, a guaranteed increase in installed output or a pressure-setting instruction. Neither the shared size nor this HF1 record establishes an SW1 seawater-element alias or a current WPS package.

Manufacturer documents checked October 21, 2026. No publication year is inferred solely from the catalog filename.

AXEON SW1-2540: the 2.5-by-40 size does not identify the membrane series

AXEON's SW1-2540 and HF1-2540 records describe different membrane series despite sharing a nominal housing-size category. Keep the series with the dimensions and rating basis before comparing a replacement.

SW1-2540 entries in AXEON specification MKT–580–C
Document field Published entry
Length and element diameter 40 inches / 1016 mm; 2.40 inches / 61 mm
Nominal housing category 2.50-inch inside diameter
Permeate flow and applied-pressure basis 500 GPD at 800 psi / 55.16 bar

The sheet describes SW1 as a fiberglass-wrapped series for high-salinity applications. Its separate warranty-evaluation note states 550 ppm filtered, dechlorinated municipal water at 77°F / 25°C, 8% recovery for the 2540, and flow variation of ±20%. Preserve that stated test basis; it does not demonstrate 500 GPD from an arbitrary seawater supply.

Compare these entries with the HF1-2540 document comparison. A shared nominal size is not evidence of equivalent feed-water conditions, output or an interchangeable installed element. The test pressure above is a document field, not a pressure-setting recommendation.

Source: original AXEON SW1 sheet, MKT–580–C, July 9, 2021, ©2021, hosted by ESP Water Products; checked October 21, 2026. No later SW1 revision or SW1-to-SE1 supersession is established here. No WPS package, availability, installation procedure or complete-system suitability is implied.

FilmTec 400/34: active area, spacer thickness and the “i” suffix

In DuPont's BW30XHR PRO-400/34 examples, 400 square feet is active membrane area and 34 mil is feed-spacer thickness. Those are separate specification fields, not the element's gallons-per-day output or its outside dimensions. Retain the full series name before comparing another 400/34 model.

Two BW30XHR PRO manufacturer records, both dated November 2024
Complete model Area and spacer Connection identity in the sheet
BW30XHR PRO-400/34 400 ft² / 37 m²; 34-LDP Supplied coupler 313198, with two 3-912 EPR O-rings, part 151705
BW30XHR PRO-400/34i 400 ft² / 37 m²; 34-LDP iLEC interlocking end caps

DuPont defines LDP as Low Differential Pressure. Both sheets publish 11,500 GPD under the same standard test conditions: 2,000 ppm NaCl, 225 psi, 77°F / 25°C, pH 8 and 15% recovery. They qualify individual-element flow as no more than 15% below that value and note that sales specifications may change with design revisions.

A shared area, spacer and laboratory rating does not make the two connection arrangements interchangeable. Keep the full suffix, applicable document revision and required connection hardware with the equipment assessment. These laboratory conditions are not operating adjustments or a promise of installed production.

Sources: DuPont 45-D03749-en, Rev. 4 and 45-D03751-en, Rev. 3, checked October 21, 2026. These named examples establish no universal code rule, WPS package, supplier availability, installation method or system-fit approval.

AXEON HF4-2521: compare the full model behind “2.5 × 21”

AXEON's HF4-2521 sheet lists a 21-inch length and a 2.40-inch element diameter, within its nominal 2.50-inch-ID housing category. The nominal size does not identify the membrane series or its performance basis.

HF4-2521 in specification MKT–571–C, May 28, 2026
Field Manufacturer entry
Permeate-flow rating 400 GPD / 1.51 m³/day
Applied pressure for that rating 100 psi / 6.89 bar
Nominal salt rejection 99%

Its warranty-evaluation basis is 550 ppm filtered, dechlorinated municipal water at 77°F / 25°C and 8% recovery for the 2521, with flow variation of ±20%. Keep those conditions with the model and revision. A rating is not a measurement of the installed system or a pressure adjustment.

The HF1-2521 reference above also uses a 400-GPD label but a different applied-pressure basis. The similar flow number and nominal dimensions therefore do not establish equivalent operation, an approved substitution or a complete RO-system configuration.

Source: original AXEON HF4-Series sheet, MKT–571–C, May 28, 2026, checked October 21, 2026. No installation, operating change, current WPS package or supplier availability is established.

FilmTec BW30 PRO-4040: keep the series name with the 4040 format

DuPont's BW30 PRO-4040 is a specific element, part 12080524. Its product sheet lists 85 ft² / 7.9 m² of active area and a 2,600-GPD permeate-flow rating. The 4040 format alone does not identify that performance.

BW30 PRO-4040 fields in DuPont 45-D03970-en, Rev. 5, October 2024
Record field Manufacturer entry
Length and outside diameter 40.0 inches / 1,016 mm; 3.9 inches / 99 mm
Nominal vessel category 4-inch inside diameter
Separately ordered coupler 89055; includes two 2-210 EPR O-rings, part 89255

The flow rating uses 2,000 ppm NaCl, 225 psi, 77°F / 25°C, pH 8 and 15% recovery. The sheet qualifies individual BW30 PRO-4040 flow as no more than 15% below the listed value and notes that sales specifications can change with design revisions. Retain the applicable revision when a retail description gives a different GPD figure.

Compare the separate LC LE PRO-4040 identity record without treating a shared format or coupler number as replacement approval. Neither a laboratory rating nor nominal vessel size establishes the installed output or complete system fit.

Source: DuPont BW30 PRO-4040 / BW30 PRO-2540 product data sheet, checked October 21, 2026. No operating setting, installation method, WPS package or availability claim is supplied.

Pentair GRO-50EN: keep the part number with the model name

Pentair's GRO encapsulated-element sheet lists three GRO-50EN part numbers with different included components. The shared model name and 50-GPD nominal label do not specify the same supplied configuration.

GRO-50EN variants in Pentair 4002874, Rev. F JL21
Part number Drain-line flow control Permeate check valve
4002574 Not included Included
4004424 Included Included
4005459 Not included Not included

The sheet's nominal 50-GPD performance uses a stated laboratory basis: 500-ppm softened tap water, 65 psig, 77°F / 25°C and 50% recovery after 25 hours, with individual-element flux variation of ±15%. Keep that basis with the element; it is not a household production measurement or an instruction to change pressure or flow control.

Pentair's separate GRO-2550 system sheet, model 161154, identifies 4004424 as its stage-3 membrane. That sheet lists a separate 10.09-GPD system production rate. The component's nominal rate and the complete system's rating are different fields with different test scope, not interchangeable promises of delivered water. Preserve the full GRO-2550 name; this reference does not establish an alias for RO-2550 or GRO-575B.

The element sheet's NSF/ANSI 58 wording is expressly limited to materials and structural integrity. It does not transfer the complete GRO-2550 system's reduction claims to a loose element or an unidentified assembly.

Sources: Pentair GRO encapsulated-element sheet, 4002874 Rev. F JL21, ©2021, and GRO-2550 system sheet, 4004870 JE25, ©2025, checked October 21, 2026 (America/Chicago). No current certifier-directory verification, retail selling quantity, WPS offer, installed fit or replacement procedure is established.

FilmTec BW30XFRLE-400/34: keep the full series with the rating

DuPont's 45-D01719-en, revision 7, February 2025, identifies BW30XFRLE-400/34 separately from the BW30XHR PRO and BW30 PRO examples in this guide.

BW30XFRLE-400/34 fields on page 1 of this manufacturer sheet
Field Published value
Active area / feed spacer 400 square feet / 34-mil LDP spacer.
Permeate-flow rating 11,500 GPD.
Salt rejection 99.3% stabilized; 99.1% minimum.
Element length / diameter 40.0 / 7.9 inches.

The flow and salt-rejection basis is 2,000-ppm sodium chloride, 150 psi, 77°F, pH 8 and 15% recovery. The sheet permits individual-element flow variation of up to 15% below the listed value. These conditions are laboratory rating fields, not equipment-setting instructions or a guarantee of installed output.

Retain XFRLE and the complete suffix with an order request. A shared 400/34 designation does not establish equivalence to another series, pressure-vessel fit, a whole-system reduction claim or current WPS availability. Manufacturer sheet checked October 22, 2026.

RO for hard water: separate mineral reduction from feed-side scaling

Two questions need separate answers: what the complete system reduces in its produced water, and whether its membrane can accept the actual feed water under the proposed conditions. A mineral-reduction claim does not, by itself, establish suitability for untreated hard feed water.

DuPont's FilmTec technical note 45-D04931-en, Rev. 1, June 2026, questions 2–3, explains that dissolved ions become concentrated in the concentrate stream. Their solubility can limit a design. It also states that the hardness and alkalinity an RO/NF system can handle depend on operating conditions.

For a proposal, retain the feed-water analysis, exact complete-system and membrane models, and the provider's documented feed limits and design basis. Keep hardness, alkalinity and TDS as separate result fields. A GPD label or a TDS reading alone does not resolve the hardness question.

This is a selection distinction, not a universal hardness cutoff, pretreatment prescription, recovery adjustment or chemical-feed instruction. It does not establish that a particular WPS component is suitable for an installation.

AXEON 200370: use the HR3-2540 row, not the series maximum

AXEON's corporate site links to AXEONSupply, where part 200370 is identified as HR3-2540. Its linked specification sheet gives:

HR3-2540 manufacturer rating, MKT-574-C
Field Published value
Permeate flow 650 GPD
Applied test pressure 225 psi
Nominal salt rejection 99.5%

The test basis is filtered, dechlorinated municipal water at 550 ppm and 25°C, with 15% recovery for this model. The sheet separately allows ±20% permeate-flow variation for warranty evaluation. These are test conditions, not controller settings or guaranteed installed output.

The series headline of 2,200 GPD belongs to the HR3-4040 row. It is not the HR3-2540 rating. This record also does not establish an HF3-to-HR3 supersession or approve a replacement solely from nominal size.

Sources checked October 22, 2026: AXEONSupply part record and its linked MKT-574-C sheet, July 8, 2021. No WPS offer, universal fit, treatment claim or service procedure is established.

Double-pass RO: does it mean two filter stages?

Double-pass RO sends the first RO system's permeate into a second RO system. Kurita America's engineering explanation distinguishes that arrangement from its two-stage vessel-array example:

Different counts describe different parts of an RO proposal
Description What to identify
Two-pass RO The first system's permeate becomes feed for the second RO system.
Two-stage 5:3 array example Five pressure vessels in the first group followed by three in the second; these are vessel groups, not two household filter cartridges.
Two cartridges or membrane elements A component count alone does not establish either flow arrangement.

If a proposal says “double RO,” request its flow diagram with feed, permeate and concentrate identified. Extra carbon stages or additional membrane elements do not by themselves prove that the product water undergoes a second RO pass.

Source: Kurita America, Reverse Osmosis Membranes: System Design, Jacob Hatt, October 23, 2023, RO Pressure Vessels and System Design; checked October 22, 2026. This is terminology guidance, not a system design, WPS offer or purity/recovery guarantee.

Reverse osmosis in wastewater treatment: what application does the proposal describe?

RO can be part of an engineered wastewater-reuse system. Applied Membranes identifies RO alongside microfiltration, ultrafiltration, nanofiltration and evaporation among the technologies used in its custom reuse systems. Its examples include industrial rinse-water and process-water applications.

Keep two meanings of “wastewater” separate:

  • Wastewater being treated for reuse: identify the original source, intended end use and complete treatment train. EPA explains that treatment and monitoring requirements vary with both the source and the use; its overview describes multiple treatment barriers.
  • A household RO concentrate stream: this is the stream separated from permeate during RO operation, as explained in the drain-water ratio record. Its existence does not establish a wastewater-reuse system.

An RO membrane or GPD figure alone does not validate an entire reuse application or drinking-water safety. Keep the provider's documented application and complete-system validation with the proposal.

Sources: Applied Membranes, Wastewater Reuse, no revision established; EPA, Basic Information about Water Reuse, updated October 1, 2026. Checked October 22, 2026. This application distinction supplies no design, operating instructions or current WPS system offer.

Hydranautics SWC4-LD: retain the suffix and test basis

SWC4-LD is the complete model on Hydranautics' February 21, 2018 specification sheet. A shortened “SWC4” request leaves part of that identity unstated.

SWC4-LD fields in the named manufacturer sheet
Field Published value
Permeate-flow rating 6,500 GPD / 24.6 m³/day.
Salt rejection 99.8%; 99.7% minimum.
Active area / feed spacer 400 ft² / 34 mil; the sheet marks these description fields as indicative.
Element length / diameter 40.0 / 7.89 inches; also marked indicative.

The performance basis is 32,000 ppm NaCl, 800 psi applied pressure, 77°F, 10% recovery and pH 6.5–7.0. Hydranautics describes normalization to those conditions and permits ±15% individual-element flow variation. These are laboratory comparison fields, not operating instructions or guaranteed installed production.

Retain LD, the applicable sheet and the complete system reference when comparing an order. The dimensions or flow number alone do not establish vessel fit, another SWC4 variant's equivalence or a complete treatment claim.

Source: Hydranautics SWC4-LD specification, February 21, 2018, checked October 22, 2026. This dated reference establishes no current WPS package or supplier availability.

Toray TM720D-400: keep the suffix with the 8040 format

TM720D-400 and TM720D-440 share an 8040 size category, but Toray lists different area, flow and spacer fields. Preserve the complete name when comparing a supplier's description.

Two separate columns in Toray's TM700D sheet, 01-MB1-01-240131
Field TM720D-400 TM720D-440
Membrane area 400 ft² / 37 m² 440 ft² / 41 m²
Product-flow rating 11,000 GPD 12,100 GPD
Minimum product-flow rating 8,900 GPD 9,800 GPD
Feed spacer 34 mil 28 mil

Both columns list 99.80% nominal and 99.65% minimum salt rejection. The common test basis is 225 psi, 77°F, 2,000 mg/L NaCl, 15% recovery and pH 7. These are rating conditions, not instructions to change equipment settings or promises of installed output.

A nearby TMG-series description is not the TM720D-400 record. Confirm the complete element and approved system specification before treating similar dimensions or flow numbers as substitution approval.

Source: Toray TM700D product datasheet, 01-MB1-01-240131, ©2024, page 1; checked October 22, 2026. No current WPS package, availability or independently verified certification claim is established.

Suggested parts

Check the exact model and fit before ordering.

Back to blog