Fleck 5600SXT parts
Confirm the control face says 5600SXT and identify downflow versus upflow from the valve configuration. Mechanical 5600 controls are a separate service configuration.
- Manufacturer
- Pentair
- Model family
- 5600
- Generations
- Electronic SXT-control variant; verify downflow or upflow configuration and valve label before selecting parts.
Model identification
Comparing service packages? Use our Fleck 5600 rebuild kit buying guide to check exact part numbers and package contents before ordering.
Choose your Fleck 5600SXT parts route
- Confirmed SXT control: use the downflow and upflow references below; match the installed configuration and full part number.
- Mechanical timer or uncertain control: compare the Fleck 5600 valve and control identification checks before using SXT-specific references.
- Model or part number unknown: start with Help me find my part.
Identify the 5600SXT and its flow configuration
Record the valve-body label, SXT controller, complete old part number and downflow or upflow configuration. A mechanical 5600 control or a similar-looking SXT face does not by itself establish the correct piston, meter or powerhead.
For a confirmed downflow softener with a service problem, use Fleck 5600SXT troubleshooting checks to record the display, symptom and cycle before choosing a part.
Choose the 5600SXT flow direction, then the assembly drawing
Use the documented downflow or upflow configuration with the valve-body and SXT-controller identity. If the control is mechanical, return to the mechanical 5600 drawing and identification guide. If flow direction is unknown, use identification help; do not choose a piston route from the display or a symptom.
Confirmed downflow — 42684 REV L MY18
| Assembly to locate | Official drawing and matching list | Keep this distinction |
|---|---|---|
| Control valve | Drawing, page 16; parts list, page 17 | Read the piston and seal/spacer entries separately; keep this downflow list separate from upflow. |
| Valve powerhead | Drawing and parts list together, page 18 | Match the documented powerhead/control revision before selecting a listed component. |
| Turbine or paddle meter | Meter drawings and parts lists together, page 19 | Use the table for the identified meter design; a cap or cable reference does not establish a complete retail package. |
Confirmed upflow — 42683 REV J NV16
| Assembly to locate | Official drawing and matching list | Keep this distinction |
|---|---|---|
| Control valve | Drawing, page 12; parts list, page 13 | Use the upflow drawing/list pair. The separate service-assembly references already explained below retain their own scope. |
| Valve powerhead | Drawing and parts list together, page 14 | Use the upflow powerhead list even when a cover or drawing resembles the downflow version. |
| Turbine or paddle meter | Meter drawings and parts lists together, page 15 | Keep turbine, paddle meter, cap and cable references separate; retain the package questions below. |
Keep the manual number/revision, drawing page, list page, item key and complete part number together. Where drawing and list share a page, still record which assembly and table you used. Continue with the existing part paths and meter/cable boundaries below; a drawing does not resolve a suffix substitution or the contents of an offered kit.
Sources: the linked Pentair downflow 42684 REV L MY18 and upflow 42683 REV J NV16 pages, checked October 16, 2026. Page labels are one-based PDF/printed pages; enter the visible page number if your viewer ignores the link. Installed revision and exact compatibility still need checking; these are not claims that the manuals are the newest revisions.
Source-backed part paths
- Downflow piston: Fleck 60102-71 piston assembly. Pentair lists this number in the 5600SXT downflow valve table, even though the part description includes “6600.” Match the full number and downflow configuration.
- Upflow piston: 60102-62 is the separate piston listed in the 5600SXT upflow service assemblies. It remains an identification reference here with no purchase link. Do not substitute the downflow piston.
- Seal and spacer service: Fleck 60125 seal and spacer kit is separately listed in the manufacturer documentation. It is a different service item from the piston assembly; retain the exact suffix when checking a replacement.
- Brine-valve service: Fleck 60032 brine valve is listed in the upflow service assemblies. Match the installed valve configuration and service diagram before ordering.
What to check for the repair
- Piston or internal sealing: identify flow direction before comparing the piston and seal-kit paths above. Do not choose a kit from a symptom alone.
- Meter or controller: record turbine versus paddle meter, cable connector, controller revision and electrical rating. Check the matching powerhead and meter drawings instead of assuming all 5600SXT controls use one assembly.
- Injector or refill: copy the complete injector and flow-control markings. Tank and flow settings must be checked in the installed system documentation; do not order from color alone.
Turbine meter, paddle meter or meter cap?
The meter drawings identify three different service choices: 60626, a 3/4-inch turbine meter assembly; 60086-50, a 3/4-inch electronic paddlewheel meter assembly; and 14716, the paddle-meter cap assembly. A cap assembly is only part of the complete meter. Match the installed meter design and controller/cable connection before ordering; these listings do not establish a conversion between meter types.
Pentair identifies the cap assembly as including callouts 2–4: 13874 cap, 13847 O-ring and 17798 screw. This describes the manufacturer drawing; confirm the offered package on the product page and ask if cable or other supplied contents are unclear.
Source locators: 42684 REV L MY18, printed page 19, and 42683 REV J NV16, printed page 15: turbine item 4; paddle items 1–4 and 13. References checked October 12, 2026.
19121-01 SXT meter cable: check the exact suffix
Pentair lists 19121-01 in both the turbine/SXT and paddle/SXT meter tables in the two manuals below. This is a documented cable reference for the illustrated configurations. Match the installed meter, connector and controller revision before choosing a replacement.
- Downflow source
- Pentair 5600SXT Downflow Service Manual, 42684 REV L MY18, printed page 19: turbine table, Not Shown list; paddle table, item 5.
- Upflow source
- Pentair 5600SXT Upflow Service Manual, 42683 REV J NV16, printed page 15: turbine table, Not Shown list; paddle table, item 5.
Keep the package question separate. Paddle item 5 says the cable is not included in P/N 60086, without a suffix. The complete paddlewheel meter is separately listed as 60086-50 at item 13. That note does not verify whether a particular 60086-50 retail package includes a cable.
Still unknown: compatibility with your equipment revision, any substitution for -03, -04 or -05, and the contents of a supplied retail package. No purchase link for an exact 19121-01 offer is verified here. Record the full number and unresolved details, then ask for identification help.
Manufacturer documents checked October 12, 2026. The revisions above identify the evidence reviewed; they are not a claim that these are the newest manuals. This is a document comparison, not a physical fit test.
Manufacturer manuals and source locators
- 5600SXT downflow service manual, 42684 REV L MY18: printed pages 16–17 for the valve drawing and parts list, including 60102-71 and 60125; page 19 for the turbine and paddle-meter drawings and parts lists.
- 5600SXT upflow service manual, 42683 REV J NV16: printed pages 14–15 for powerhead and meter configurations; page 27 for 60102-62, 60125 and 60032 service assemblies.
Evidence reviewed October 12, 2026. Match the source to your equipment revision; these references do not establish interchangeability with mechanical 5600 or other Fleck valve bodies.
Related resources: Fleck parts, Fleck 5600 identification guide, and the exact part-number index. For an uncertain label or configuration, send the complete part number and valve/controller details.
Before ordering
Open the exact product page for the offered part and current orderability. Supplier availability is confirmed after ordering; payment is authorized before capture. Review shipping and ordering and the return policy before purchase. These part maps support identification, not diagnosis. Follow the matching manufacturer service instructions and use a qualified service professional when needed.
Parts linked to this model
Only products with verified fitment evidence are listed here. Confirm the exact valve label, service position, and configuration before ordering.
Use the model documentation to identify the exact part
No saleable part is linked to this model without verified fitment evidence. The identification guidance and documented links on this page remain available.
Frequently asked questions
Use the manual matching the flow configuration. Match the OEM part number, piston configuration, and control revision before ordering.