Control Valve Replacement Parts Identification Guide

Use the valve-body label and the exact order number before selecting a service component. A control face, a loose seal, or a similar-looking assembly does not establish the valve body or included contents.

Identification checklist

  1. Photograph the complete valve-body label and record the exact order number.
  2. Record whether the document identifies a complete assembly or a component within it.
  3. Confirm flow/configuration and any suffix in the source document before ordering.
  4. Use the applicable manufacturer service document for the final identification check.

Record the valve, riser and distributor seal together

A search for a riser tube or distributor O-ring does not identify the seal used by a particular valve. Copy the following details from safely visible external labels, the matching manual and existing installer records. Write “unknown” for anything those records do not establish; do not remove parts to complete this record.

  1. Equipment: manufacturer, complete valve-body model and revision; record the controller separately.
  2. Distributor/riser: the documented tube-opening size and units, plus the valve-body configuration to which that size applies.
  3. Seal: complete OEM number and suffix, its named position, and whether the drawing shows a seal or a larger assembly.
  4. Source: document number/revision, printed page and drawing callout. Keep the source attached to the identification record.

The Clack WS1.25 V3358/V3357 riser O-ring example shows separate references for 1.32-inch and 32 mm distributor-tube openings. Use that model-specific locator rather than choosing a seal from a loose part’s appearance or converting the two entries into an interchangeable size.

Source: Clack V3115-99, January 21, 2026, printed page 7, callout 8. For a hard-water complaint, the not-softening observation guide records the symptom separately. This label-and-document record identifies hardware; it does not diagnose the cause or establish that replacing a seal will reduce hardness.

Injector, venturi, cap or screen: choose the model reference first

If a search or equipment note says “injector” or “venturi valve,” keep that wording in the record, then identify the manufacturer and valve body. The term alone is not a complete part number and does not establish whether the required item is an injector, cap, cover, screen or assembly.

  • Clack WS1/WS1.25: the manufacturer drawing lists V3176 injector cap, V3152 O-ring and V3177-01 screen cage separately from the injector and plug. Use the Clack WS1 injector references and drawing locator to retain the complete component number and its valve configuration.
  • Fleck 5600: the parts table separates the injector body, nozzle and throat from 10227 screen and 13166 cover. Use the Fleck 5600 model guide with the matching manual. These Fleck names and numbers do not establish a Clack replacement or a cross-brand equivalent.
  • Comparing a component listing: after identifying the valve and exact OEM number, use the injector parts category to distinguish the named component from a larger assembly. A cap, screen or cover reference does not establish the contents of a complete injector package.

Sources: Clack V3115-99, January 21, 2026, printed page 8, callouts 1–5; Pentair Fleck 5600 manual 40106, printed page 13, items 22–26. These are component-identification routes, not cleaning, replacement or diagnostic steps. References checked October 14, 2026.

Injector draw, tank refill or drain flow: are these the same control?

No. They describe different flow paths and different parts of a regeneration record. Clack's WS1/WS1.25 component descriptions provide a named example. Keep that valve scope with the explanation rather than applying one component number or flow value to every softener.

Three distinct functions in Clack Form V3115-99
Component or process Documented role What the label alone does not tell you
Injector and regenerant draw The injector accelerates water to produce suction, drawing concentrated liquid regenerant into a water stream that passes through the media. It does not set the entire refill or backwash program, or identify a failed part from a salt-use symptom.
Refill flow control Controls the water flow when the regenerant tank is being refilled. A refill-rate reference is not the injector's draw rate or a universal normal tank-water height.
Drain line flow control Regulates discharge to the drain to support media-bed expansion during backwash. A drain connection size alone does not select the required backwash rate.

The manual's injector discussion also separates regenerant draw, slow rinse and total flow in its graphs. When a service record includes a rate, retain which quantity is being described, its units, the documented inlet-pressure condition and the exact injector or flow-control reference. A number without that context cannot be transferred between the three rows above.

For an order enquiry, identify whether the requested item is the injector, its screen or cap, a refill component, or a drain flow-control component. Use the Clack injector number/color and drawing reference for identity, and the separate brine-tank component record for a float, air check or tank fitting. Keep unknown internal conditions unconfirmed; these descriptions do not diagnose a clogged injector or select a repair.

Source: Clack Form V3115-99, January 21, 2026, printed page 29, injector and refill descriptions, and printed page 30, drain flow-control description. No cleaning, disassembly, adjustment, flow-rate selection or programming procedure is supplied.

Fleck NXT2: record the timer assembly and valve separately

NXT2 identifies a Fleck timer/controller family. Record the installed valve model and complete component number before comparing a timer, programmed control panel or communication cable. The NXT2 name alone does not identify a complete valve or a replacement for another controller.

NXT2 timer and control-panel references
Complete reference Manufacturer locator Component boundary
62115 Printed page 14, item 1, timer assembly drawing for the documented 2510/2750/2850/2900/3150/3900 valve group. NXT2 timer assembly. The current catalog lists a single selling unit; retain the exact valve and revision record.
62115-01 Printed page 15, item 1, separate 2815 timer assembly drawing. The 2815 reference has its own suffix. Do not treat it as an alias of 62115 or choose from the NXT2 name alone.
62120 Printed pages 14–15, item 2. Programmed control-panel assembly, separately listed from the complete timer assembly. This is an OEM identification reference here, not a claim about a timer order's shipped contents.

The manual's printed page 18 separately labels communication cables, meter cable and power supply. The current 61763 catalog record names a CAT5 network communication cable for NXT2 controllers, with a single selling unit. The manual does not print that cable number; keep the supplier number and installed system documentation together rather than treating a cable as a timer, meter cable or power supply.

Source: Pentair Fleck NXT2 Timer Service Manual, 44381 REV D NO23, printed pages 14–15 and 18. This PDF displays paired printed pages, so use the printed-page headings. References checked October 15, 2026. These locators do not establish a controller upgrade, network interoperability, retail bundle contents, wiring or programming instructions.

RainSoft Gold Series: distinguish the motor from the board and cam gear

A search for “RainSoft motor” needs the equipment series and matching document. In the Gold Series manual below, the motor, board and brine-cam gear have separate references. This is one documented Gold Series example, not an identification of every RainSoft valve.

RainSoft 15860b control drawing and parts list
Complete number / callout Named component Identification boundary
17537 / 4 Valve motor with computer cam; the parts list states 24 V, 50/60 Hz. The motor entry includes a cam in its name. The drawing does not establish a retail package or a motor for another series.
17527 / 11 Gold printed-circuit-board assembly; the list also states 24 V, 50/60 Hz. A matching voltage/frequency description does not make the board a motor or prove replacement equivalence.
17501 / 2 Brine-cam gear. This is separately named from the motor with computer cam. Record which component is being requested.

Source: RainSoft Gold Series manual, part 15860b, revised 12/06, printed page 14 control drawing and page 15 parts list. Match the model, serial and equipment document to this reference before comparing numbers. These are OEM identification references here; no offer, Fleck motor alias, diagnosis, electrical work or installation procedure is established. Reference checked October 15, 2026.

Fleck seal, injector body or kit: keep the complete scope and position

The following manufacturer locators distinguish an individual component from a kit and separate upper from lower positions. Match the valve-body model, complete number, suffix, document revision and drawing position; a number fragment or an overlapping family name does not establish the required order.

Model-specific Fleck component boundaries
Reference Manufacturer locator Buying-record boundary
16101 2850 manual 16510 REV P AP21, printed page 22, item 2: an individual 2850 seal. Item 25 separately names seal-and-spacer kit 60129. The drawing's six seals are an assembly quantity, not a retail selling unit or a claim that one seal is the complete kit.
17777 Same manual, printed page 28, item 21: 1700 injector body. Item 26 separately names injector-cap references. The current catalog separately names 17777-01, 1700 injector assembly, body and cap, with a single selling unit. Retain that complete suffix; this locator does not establish that 17777 and 17777-01 are the same component or prove every shipped item.
61530 / 61530-01 Pentair manual 41689-S REV A JA15, Spanish edition: the printed page 51 kit list distinguishes the upper seal-and-spacer kit from its upper hot-water entry. The current catalog names 61530, 2900S upper and 61530-01, 2900S upper hot water, each with a single selling unit. Position and suffix remain part of the record; no interchangeability is asserted.
3900: 60131 / 60132 3900 NXT/NXT2 manual MKT-IM-015 / F, dated 04.12.2025, printed page 167: NAM column, item 5 upper seal-and-spacer references include 60131; item 10 separately names 60132 for the lower position. 60131 is an OEM locator here. The current 60132 catalog record names the 3900 lower kit with a single selling unit. Upper and lower positions are distinct; the NAM and EMEA columns are separate source identifiers, not automatic retail equivalents.

Sources: Pentair 16510 REV P AP21, printed pages 22 and 28; Pentair 41689-S REV A JA15, Spanish edition, printed page 51; Fleck 3900 NXT/NXT2 Installer Manual, MKT-IM-015 / F, 04.12.2025, printed page 167. The 3150 NXT/NXT2 manual, MKT-IM-010 / G, 31.10.2025, has its own valve-parts table on printed page 166. Use this separate parts table with the complete valve/controller labels and applicable manual revision.

References checked October 15, 2026. These locators identify component scope; they do not diagnose a fault, establish retail kit contents or provide disassembly or replacement instructions. Use the exact catalog record only after the equipment and source reference agree.

Fleck 60121: retain the dated manufacturer reference

Pentair's Spanish Fleck 2750 Downflow service manual, 42327-S Rev A JA15, ©2015, provides a historical reference for 60121. Printed page 18, item 31, names a seal kit and lists 1500, 2510 and 2750. Its printed page 42 service list describes 60121 as 2750 seals and spacers and lists 60122 separately for hot water. The edition is identified on page 44.

Keep this historical locator with the exact installed model, configuration and service record. It does not verify a current seller's package, shipped quantities or materials, a 60121C alias, a supersession, or a complete valve/rebuild kit. Installed applicability and the current offer still require separate confirmation. This reference also supplies no piston-kit-number correction and does not resolve a conflicting 61670 suffix. Source checked October 16, 2026; no purchase or replacement recommendation is made from the dated listing alone.

Fleck 9500: upper or lower piston, assembly or seal kit?

The 9500 table distinguishes a piston from a piston assembly and separates upper from lower positions. Keep that component level and position with the complete number when comparing a service request.

Manufacturer locators in Pentair 40944 REV L MA21
9500 position Piston, page 16 Piston assembly, page 17 Seal-and-spacer reference, page 17
Upper 17110; item 10 60108; item 42 60134; item 44
Lower 17111; item 20 60109; item 43 60133-01; item 45

The same source separately lists suffixed assembly and seal-kit alternatives. Retain the installed configuration and complete variant; a matching position alone does not select a material or temperature application. A piston number and a larger assembly number are not interchangeable order descriptions, and this table does not establish a retailer's supplied contents.

Source: Pentair 40944 REV L MA21, printed pages 16–17, checked October 20, 2026. The shared 9000/9100/9500 title does not establish cross-model fit. These are 9500 manufacturer references, not a current Water Parts Supply offer, diagnosis or repair procedure.

Fleck 2850: distinguish the seal-and-spacer assembly from the piston configuration

For a documented 2850, retain the applicable assembly drawing and complete part number. Pentair's 16510 REV P AP21 manual, printed page 22, lists separate seal-and-spacer and piston assembly entries in the control-valve parts table. Those assembly numbers are different records from an individually numbered seal.

Exact 2850 manufacturer assembly entries with separate catalog units
Complete assembly number Manufacturer entry on printed page 22 Current catalog selling unit
60129 Item 25: 2850 seal and spacer kit, stated for cold and hot water. Single
60129-20 Item 25 alternative: 2850 seal and spacer kit, plastic spacers and chemical-resistant seal. Single
60114-01 Item 24: 2850 piston assembly, NHWBP, replacement entry. Single

Keep the -20 suffix with the documented spacer/seal configuration; the table does not select a material for a particular installation. The piston row retains the manufacturer's NHWBP wording. The linked catalog uses “No Raw Water Bypass”; preserve both source records and resolve the applicable configuration rather than treating wording alone as fitment proof. A piston or seal-and-spacer assembly is not a complete valve order.

Record the exact installed valve/configuration, manual revision, page/item, complete assembly number, listed unit and separately confirmed contents. The manual's service-assembly list on printed page 50 also identifies 60114-01 as a 2850 NHWBP piston assembly. These component locators do not establish a current NXT2 complete-valve variant, a conversion, a regeneration plan or an installation/service offering.

Sources: Pentair 16510 REV P AP21, printed pages 22 and 50; form/revision on page 52. The three linked current catalog records supply their separate single selling units. Checked October 15, 2026. No part interchangeability or assembly-content claim is inferred from the drawing.

Fleck 2900S: identify the upper or lower piston assembly

Pentair's dated Spanish manual separates upper piston assemblies by flow direction and lower piston assemblies by bypass configuration. Keep the named position and variant with the complete number; “2900S piston” alone leaves that decision unresolved.

2900S piston-assembly references in 41689-S Rev. A, JA15, printed page 19
OEM reference Position Documented variant Drawing item
61540 Upper Downflow 33
61545 Upper Upflow 33
61550 Lower DAD: hard-water bypass 36
61555 Lower SDAD: no hard-water bypass 36

The drawing separately marks upper and lower seal-and-spacer kits as items 34 and 35. These piston-assembly entries are not a complete valve, a retailer's rebuild bundle or proof that a supplier's casting description identifies the same assembly. Confirm the complete component reference and offered package separately. No conversion, material selection, current offer or cross-generation fit is established here.

Source: Pentair 41689-S Rev. A, JA15, ©2015, printed pages 18–19; the four base assembly descriptions also appear on page 50. Page 2 names the bypass configurations; page 52 identifies the edition. Rechecked October 18, 2026. Match the applicable installed-system documentation before selecting a part.

For a documented 7000SXT, use the Fleck 7000SXT diagram and parts identification guide to distinguish the powerhead, valve and bypass references while retaining complete cover and BSP connector suffixes.

Whirlpool WHES18: bypass assembly or nozzle and venturi kit?

For a documented WHES18, keep the bypass request separate from the nozzle-and-venturi request. The valve drawing and parts list below give them different references. “Whirlpool” or “venturi valve” alone does not identify the model or the component being ordered.

WHES18 valve references in manual 7385281, Rev. H
OEM reference Named item and locator Component boundary
7370286 Printed page 23, key 71: bypass valve assembly, described as 3/4 inch, including two O-rings referenced at key 72. The assembly is separate from the O-ring entry. The printed size description does not establish another thread type, another system's fitment or the contents of a retail order.
7398705 Printed page 23: nozzle and venturi kit, including keys 76–78. Those keys name the retainer, O-rings and nozzle-and-venturi assembly. The internal key numbers are drawing callouts; this list does not print separate order numbers for those three entries.

The exploded view is on printed page 22. Copy the complete system model, manual revision, named component and full number from the matching view. A kit or assembly name in this document is an OEM identification reference here, not a WPS offer or a guarantee of a supplied package.

Source: Whirlpool WHES18 Installation and Operation Manual, 7385281, Rev. H, January 30, 2025, printed pages 22–23. These references do not identify other Whirlpool models or provide nozzle cleaning, flow-plug orientation, bypass operation or replacement instructions.

Flow straightener or complete meter assembly?

A request for a flow straightener needs the meter reference and the component's complete number. Pentair's Fleck 9000/9100/9500 manual lists a flow straightener separately from the meter body, impeller and complete meter assemblies in these two tables:

Flow-straightener component references in two named meter tables
Manufacturer table Component reference Keep the assembly separate
1-inch Meter Assembly, printed page 24 Item 7: 14960, Flow Straightener, 1-inch The table separately lists meter body 15043 and complete meter-assembly references.
1-1/2-inch Brass Meter Assembly, printed page 25 Item 7: 17542, Flow Straightener, 1-1/2 inches The table separately lists meter body 17569, impeller 13509 and complete meter-assembly references.

The same item number in two drawings does not identify the same part. Retain the table title, meter configuration and complete component number; a request for item 7 does not by itself specify a complete meter or verify the retailer's supplied package.

Source: Pentair Fleck 9000/9100/9500 service manual 40944 Rev. L MA21, printed pages 24–25. These are manufacturer component locators, not a universal valve fit, flow-performance result or installation procedure.

For a 9000/9100 meter-related request, use the meter, cable or checker-kit identification record before comparing component numbers.

Maytag ST series: motor, drive bracket or circuit board?

For a Maytag water softener maintenance record, keep the system model and the requested drive component separate. The ST-series manual W11572554A, dated 04/22, lists model patterns including 3M-ST32-XXX on printed page 9. Copy the complete installed model and suffix from your records; the printed XXX pattern does not identify an individual unit.

Separate references in the front-cover and drive table, printed page 36
Manufacturer number Drawing item Component
V3107-01 2 Motor
V3002-A 3 Drive bracket assembly
V4404LD-BOARD 4 LD PC board

Retain the manual revision, page and item with the full component number. These separate entries do not establish another Maytag model's fitment, a complete valve, a retailer's package contents or an equivalent part under another brand.

Source: Maytag ST Series Operation Manual, W11572554A, 04/22, printed pages 9 and 36, Figure 26. The manual excludes internal user repair of the motor, board and adapter. These locators provide identification only; they do not diagnose a fault or give replacement instructions.

Morton M27 and M34: match the manual, board and faceplate decal

For a Morton M27 or M34 water softener manual, use the model links in Morton's owner-manual archive. Both link to Installation and Operation Manual 7388336, Rev. G, January 31, 2025. Its cover names M20, M27, M30, M34 and MC30; its parts table separates the models at each component:

Morton manual 7388336, printed page 25: Softener Parts List
Models named in the row Key 15: electronic board (PWA) Key 13: faceplate decal
M20, M27, M30 and MC30 7331818 7331371
M34 7331834 7331630

The exploded view on printed page 24 marks the board and decal separately. Keep the complete model and serial number, manual revision, component name and key number with your record. A faceplate-decal number does not identify the control board; sharing one manual does not make the two board numbers interchangeable. These documentary references do not establish a superseding number or a match for an unidentified Morton model.

Manufacturer source and rendered pages checked October 15, 2026.

Fleck 5600SE Downflow: find the valve, powerhead or meter drawing

The archived 5600SE Downflow Service Manual, P/N 19742 Rev. F separates the valve, powerhead, meter and bypass drawings. This public copy is hosted by Good Water Warehouse; it is an archival reference, not a verified current manufacturer download.

Drawing locations in the reviewed 32-page archive
Component record Printed pages and figure
Control valve assembly Pages 16–17; Figure 15 and its parts list
Valve powerhead assembly Pages 18–19; Figure 16 and its parts list
Turbine meter assembly Page 20; Figure 17
Plastic or brass bypass assembly Page 21, Figure 18; page 22, Figure 19, respectively

Keep the complete installed model, document revision, printed page, figure, local item number and part description together. A drawing's item number is not a manufacturer's ordering code. These locators do not establish current replacement availability, package contents or fit for an unidentified valve.

Retain the SE suffix. Use the separate mechanical 5600 reference or 5600SXT reference only when that complete model matches. This archive does not establish SE/SXT interchangeability and supplies no new programming, wiring or repair instructions here.

Archive cover, revision and drawing locations checked October 20, 2026. No publication date is inferred from the filename.

Fleck 3900 manual: valve reference or remote-meter document?

Read the cover title as well as the filename. Pentair hosts a file whose name includes “3900” but whose cover identifies a Model 1000 remote reset meter. It is a different reference from the 3900 NXT/NXT2 valve manual already used for the component examples above.

Document Verified scope
Fleck 3900 NXT/NXT2 Installer Manual, MKT-IM-015 / F, 04.12.2025 3900 valve and NXT/NXT2 configurations; separate valve, powerhead and meter parts sections.
Model 1000 Remote Reset Meter Service Manual, 15369 Rev C SE10 Remote-meter and reset-timer assemblies, including separate meter-size drawings.

Record which component you are identifying, its actual model and the document revision. Do not use a filename match as approval to apply a meter document to a valve or controller. This comparison reproduces no settings, wiring, installation or repair steps and establishes no current-edition or installed-fit guarantee.

Fleck 60102-00: keep the piston-assembly suffix

60102-00 identifies a piston assembly, not a complete control valve or a seal-and-spacer kit. Pentair's dated 4650 service manual separates these entries in its service-assemblies table:

Assembly references in Pentair 40261 Rev. E MY17, printed page 15
Complete reference Manufacturer description
60102-00 Cold-water softener piston assembly
60102-10 Cold-water feeder/filter piston assembly
60102-20 Cold-water low-water piston assembly

The separate WPS 60102-00 record is supplier-described as a 5600 standard piston assembly with white end plug, offered as single. Preserve that complete seller description and unit with the exact code.

The shared 60102 prefix does not make the three assemblies interchangeable. The 4650 document is a manufacturer identity reference, not a new compatibility list for every 4650, 5600 or SXT configuration. Match the installed valve and its applicable parts list; an end-plug color alone does not identify the full assembly.

Source: Pentair Fleck 4650 manual, service assemblies, and the linked supplier record, checked October 20, 2026 (America/Chicago). No supersession, package-inclusion beyond the stated unit, stock or repair procedure is inferred.

Example part identifiers

These examples identify documented parts, not universal fitment.

  • V7103-12 / V7B82B12 — V7103-12 / V7B82B12 Watts / Clack Flo-et Flow Control Button - 12 GPM
  • V7103-5 / V7B62B5.0 — V7103-5 / V7B62B5.0 Watts / Clack Flo-et Flow Control Button - 5 GPM - Blue
  • V7103-6 / V7B62B6.0 — V7103-6 / V7B62B6.0 Watts / Clack Flo-et Flow Control Button - 6 GPM - Red

If you are deciding whether to repair the existing system, use the water softener repair-or-replacement worksheet to compare documented findings and complete quotes.

Related parts and help

Browse control valve parts · Part references · Ask for fitment help

Sources reviewed

Review date: 2026-10-02. October 2026 supplier assortment records; Clack Domestic Water Specialist service-parts document 3264 · Pentair Fleck control-valve manuals · Pentair Autotrol 255 Performa service manual. Manufacturer documentation controls technical claims and fitment.

Fleck 2510 AIO: air-check assembly or coupling adapter?

Keep AIO with the model when selecting the drawing. The Pentair Fleck 2510 AIO Control Valve manual, 44425 Rev. B AP24, lists these separately in its control-valve assembly table on printed page 9:

Separate 2510 AIO component references
Item Part number Manufacturer description
15 62116 Air-check assembly, 2510
17 19228-02 Adapter assembly, coupling, 2510 AIO

These are two component identities, not interchangeable names or a combined kit. Retain the complete installed model, manual edition and drawing item with the request; a generic 2510 label does not establish the AIO configuration or another valve's component match. The table also does not identify a complete iron-filter system, its medium or a verified treatment result.

This manufacturer-authored manual copy is hosted by SWT and was checked October 21, 2026. The references provide no fault diagnosis, service interval, pressure setting, installation or replacement procedure. Confirm the actual offered component and package separately before ordering.

Fleck 3900 upper piston: preserve the flow-configuration suffix

For an upper-piston request, Pentair's 3900 NXT/NXT2 manual, MKT-IM-015 Rev. F, December 4, 2025, section 11.1, lists 60106-00 in the NAM column for the 3150/3900 upper downflow piston assembly, and 60106-10 for the upper upflow piston assembly. The full suffix therefore remains part of the component identity.

These are piston assemblies, separate from the upper/lower seal-and-spacer references above. A 3900 body label alone does not select the flow configuration, and this comparison is not a conversion recommendation. Retain the installed configuration, controller generation, regional column and applicable document with the request.

This dated manufacturer reference was checked October 21, 2026. It establishes no current WPS package, interchangeable replacement, controller upgrade, fault diagnosis or service procedure.

Fleck 2510SXT control head: retain the configured valve number

Pentair's 2510 SXT page lists several configured valve numbers. A request for a “digital metered 2510SXT control head” needs more than the shared family name. Keep the complete item description with the installed valve and controller record.

Selected identity fields in Pentair's 2510 SXT item table
Manufacturer item Listed control / application distinction
251006-003 Time clock; downflow backwashing filter.
251006-004 Turbine meter; downflow softener.
251006-005 Paddle-wheel meter; downflow softener.

These are selected fields from configured-valve descriptions, not replacement circuit-board numbers or a complete contents list. “Metered” alone does not distinguish the two meter configurations above. Confirm the complete applicable parts reference before selecting a board, powerhead or valve assembly.

Source: Pentair Fleck 2510 SXT valve reference, checked October 21, 2026; no page revision displayed. Pentair marks this valve discontinued. That status does not establish replacement-part availability or authorize substituting a 2510 AiQ or AIO assembly. No WPS offer, fit or operating change is established here.

Morton M45C manual: keep the document number and revision

For an M45C label, use Morton's separate M45C manual archive. The M27/M34 reference above does not establish the applicable M45C instructions.

Two manufacturer-hosted M45C document identities checked October 21, 2026
Document Cover revision and date Archive context
7403576 Rev. B, March 10, 2026 M45C manual attachment
7393349 Rev. F, January 31, 2025 The archive's 2025 link, labelled for the earlier iQua app

Both covers identify M45C, and both contents pages locate exploded views and parts lists on printed pages 28–31. Retain the installed model, serial information and applicable document revision before using a drawing to identify a component. The archive also separates older versions; a newer cover date alone does not prove compatibility with every earlier unit or an app/controller upgrade.

This is a document locator and revision comparison. It reproduces no settings, wiring, installation, regeneration or repair instructions and establishes no WPS replacement offer.

Aquasure manual PDF: confirm the series before using the drawing

For equipment labeled Harmony Series, Aquasure's support article links the Harmony owner's manual marked V5001 • 04/26. Retain the complete installed label and document edition; an Aquasure brand name alone does not establish that this family manual applies.

Choose the document route from the equipment label
What you can identify Manufacturer route
Harmony Series Harmony support article and attached PDF; compare its edition with the equipment.
Another series, or series unknown Use Aquasure's manuals and documentation hub to establish the series before choosing a document.

In the linked Harmony edition, printed page 3, PDF page 6, separates the digital control valve, hydraulic meter and bypass in its component drawing. Those callouts identify different components; they are not individual order codes or evidence of a Clack or Fleck substitute.

Manufacturer sources checked October 21, 2026. This locator establishes no WPS offer, installed-generation match or replacement fit, and supplies no installation, programming, salt, regeneration or service procedure.

Fleck 5000 parts: identify the ProFloSXT downflow reference

Pentair's ProFloSXT Downflow manual includes a 5000 valve-body entry. Its separate component and service-assembly lists help distinguish the following references:

Selected references in Pentair 42772 REV C SE14
Reference Documented component scope
18815 Valve-body assembly identified as 5000, 1-inch distributor, downflow; printed page 15, item 1.
18265 Separate 5000 downflow piston; printed page 15, item 5.
60115-00 / 60120 Page 29 lists a piston assembly and a separate seal-and-spacer kit, respectively. A piston component is not automatically the complete assembly or both kits.

Use the installed valve and controller labels together with the matching revision before comparing these numbers. A 5000 request alone does not establish that ProFloSXT downflow, another controller, an upflow version or another regional configuration applies. The manual's occasional 5600 component descriptions do not make the complete valves interchangeable.

Source checked October 21, 2026: Pentair ProFloSXT Downflow, 42772 REV C SE14 (©2014), printed page 15 and page 29. These are identification references, not current WPS offers, package guarantees, diagnoses or replacement instructions.

Fleck spring retainer 14253: separate the retainer, spring and clip

A spring retainer is not necessarily the spring itself or a spring clip. Pentair's 9000/9100/9500 manual distinguishes these numbers in its 3200-series electromechanical timer parts list:

Separate component names in the cited timer reference
Part number Manufacturer description
14253 Retainer, clutch spring
14276 Spring, meter clutch
14265 Clip, spring

Keep the complete number and the applicable timer drawing with a parts enquiry. Similar names do not identify the same supplied component, and the shared manual title does not make these a universal replacement set for every Fleck controller.

Source: Pentair 40944 Rev. L MA21, 9000/9100/9500 (3200 Series) Electromechanical Timer Assembly parts list, checked October 21, 2026. Component identification only; no timer adjustment, disassembly, repair, WPS package or stock claim.

Fleck 5600SXT filter valve or complete carbon-filter package?

A configured valve number does not identify the contents of a complete carbon-filter system. Pentair's 42684 Rev. L MY18 manual lists 560006-007 under “56SXT Backwash Filter Time Clock.” That heading identifies a particular valve/control reference, rather than a metered-softener package or a complete treatment-system specification.

Package boundary in the cited manufacturer reference, printed page 13
Record What the manual establishes
560006-007 A listed backwash-filter time-clock valve reference.
Explicit exclusions for this list Bypass assembly, yoke assembly, drain-line flow control with retainer, and flow washers are not included in the listed numbers.

Keep a seller's complete tank, media, controller and accessory contents beside the exact valve record. The manufacturer entry does not establish a retailer's supplied carbon volume, tested treatment claim or installed-system suitability. A shared 5600SXT name does not supply those missing package details or authorize changing a control configuration.

Source: Pentair Fleck 5600SXT Downflow manual, 42684 Rev. L MY18, page 13, checked October 21, 2026. Historical manufacturer identification only; no programming, installation, repair, current WPS offer or availability claim.

Fleck DLFC: flow washer or retainer with O-ring?

Pentair's Fleck 5600 accessories table identifies the flow washer separately from the part that retains a DLFC button:

Selected entries on printed page 17 of manual 40106, Rev. N JA23
Complete part number Manufacturer description
12090 Flow washer, 3.5 GPM
13173-01 DLFC button retainer with O-ring

The 3.5-GPM entry identifies this washer; it is not the complete valve's service-flow rating or a backwash recommendation for every tank. Preserve the full retainer suffix and stated contents rather than silently treating a plain 13173 listing as the same supplied package.

Source: Pentair 40106, Rev. N JA23, printed page 17, checked October 22, 2026. Match the installed valve and applicable configuration before comparing components. This record establishes no CSI cross-reference, universal fit, current WPS availability or instructions for changing a washer, selecting a flow rate or adjusting a system.

Fleck meter checker: standard or extended-range kit?

A meter-checker kit is a service-equipment reference, not the name of an installed flow-meter assembly. Pentair's Fleck 2850S manual lists two separate identifiers under Service Equipment:

Manufacturer kit names in the archived parts list
Part number Printed description
60460 Meter Checker Kit, Std
60461 Meter Checker Kit, Ext

Keep the complete kit number and range designation with a parts enquiry. This list does not establish that the two kits are interchangeable or specify their contents. Have the provider confirm the exact meter/control configuration and applicable equipment reference before selecting a kit; a changed water-delivery symptom does not identify one.

Source checked October 22, 2026: Pentair Fleck 2850S manual, 42319 REV G MY16, printed page 54. Historical identification only; no current WPS offer, availability, operating or diagnostic procedure is established.

Fleck 17772: keep the seal number and manual context together

A “chemical-resistant silicone” description is not enough to identify a valve seal. The saved part reference 17772 appears in two Pentair parts lists with different description detail:

Historical manufacturer references for 17772
Document and locator Part-list description
Fleck 5600, 40106 REV N JA23, printed page 13 17772: silicone seal.
Fleck 4650, 40261 REV E MY17, printed page 7 17772: seal identified for 4650, HW and chloramine resistance.

These entries identify a named component in those editions. They do not establish resistance to every chemical or concentration, a current replacement-kit equivalence, or compatibility with an unidentified valve. “Chloramine resistant” describes the listed seal; it is not a claim that the seal removes chloramine from water.

Keep the complete valve configuration and applicable current parts reference with the order. Sources checked October 22, 2026: Pentair's 5600 parts list and 4650 parts list. Historical identification only; no disassembly, seal replacement, lubrication procedure, current WPS offer or material-substitution recommendation is supplied.

Suggested parts

Check the exact model and fit before ordering.

Back to blog