A Clack WS1 or WS1.25 control valve shows an error code when the board cannot see the motor turn, the motor stalls, or the piston takes too long to reach the next cycle or home position. Depending on the board generation, the same fault displays three ways: E1, Err 1001 or Err 101. This guide lists every code in Clack's WS1 & WS1.25 service manual, the causes and fixes Clack gives for each, and the exact parts that apply when the fix is a replacement. For the full parts list and model reference, start at the Clack WS1 parts hub.
First step for any code: resynchronize
Clack's recovery for most codes ends the same way: press and hold NEXT and REGEN together for 3 seconds, or unplug the power for 5 seconds, so the board finds the piston position again. If the code returns, work through the causes below in order. Disconnect power before opening the valve.
Clack WS1 error codes at a glance
| Display | Meaning (Clack wording) | Most likely area |
|---|---|---|
| E1 / Err 1001 / Err 101 | Control unable to sense motor movement | Motor, motor wiring, PC board seating, reduction gears |
| E2 / Err 1002 / Err 102 | Motor ran too short, unable to find the next cycle position, and stalled | Debris or binding in the piston and spacer stack, tight main drive gear, supply voltage |
| E3 / Err 1003 / Err 103 | Motor ran too long, unable to find the next cycle position | Motor failure mid-regeneration, worn or fouled piston and stack, drive bracket not snapped in |
| Err 1004 / Err 104 | Motor ran too long and timed out trying to reach home position | Drive bracket not snapped in |
| Err 1006 / Err 106 / Err 116 | MAV, SEPS, NHBP or AUX MAV motor ran too long, unable to find park position | Programming, MAV/NHBP motor connection or engagement, fouled piston and stack |
| Err 1007 / Err 107 / Err 117 | MAV, SEPS, NHBP or AUX MAV motor ran too short (stalled) looking for park position | Debris or binding in the MAV/NHBP valve |
Error 1001 (E1, 101): control unable to sense motor movement
- Motor not fully inserted, or wires broken or disconnected: disconnect power, make sure the motor is fully engaged with the pinion, check for broken wires and confirm the two-pin connector is on the motor. If the motor itself has failed, the control-valve motor is the Clack V3107-01 motor assembly.
- PC board not snapped into the drive bracket: snap it in properly, then hold NEXT and REGEN for 3 seconds. If the board is damaged, match the replacement to your controller: V3108 five-button board (WS1), V3818TC time clock board (WS1 and WS1.25 TC) or V3408EE-02BOARD four-button board (WSEE series).
- Missing reduction gears: replace the missing gears.
Error 1002 (E2, 102): motor ran too short and stalled
- Foreign material lodged in the valve: open the valve, pull the piston assembly and the seal and spacer stack, and inspect them.
- Mechanical binding: check the piston and stack, the reduction gears, and the interface between the drive bracket and main drive gear. If the piston or stack is scored, swollen or will not slide freely, replace it: V3011 downflow or V3011-01 upflow piston with the V3005-02 spacer stack on a WS1, or the V3407 piston with the V3430 spacer stack on a WS1.25.
- Main drive gear too tight: loosen it.
- Wrong voltage at the PC board: verify the power supply delivers the correct voltage.
Error 1003 (E3, 103): motor ran too long, could not find the next cycle
- Motor failure during regeneration: check the motor connections, then hold NEXT and REGEN for 3 seconds to resynchronize. If the motor will not run, replace it with the V3107-01 motor assembly.
- Build-up on the piston and stack creating drag: Clack's fix is to replace the piston and stack assemblies (parts below).
- Drive bracket not snapped in, so the reduction gears and drive gear do not mesh: snap the bracket in, then resynchronize.
Error 1004 (104): motor timed out reaching home position
Clack lists one cause: the drive bracket is not snapped in far enough for the reduction gears and drive gear to mesh. Snap the bracket in properly, then hold NEXT and REGEN for 3 seconds.
Errors 1006 and 1007: MAV and no-hard-water-bypass valves
These codes only apply when a motorized alternating valve (MAV), SEPS, no-hard-water-bypass (NHBP) or AUX MAV is fitted or programmed.
- 1006 (106, 116): the valve is programmed for ALT A, ALT b, nHbP, SEPS or AUX MAV with no MAV or NHBP attached (resynchronize, then reprogram); the MAV/NHBP motor is not plugged into the board connection labeled DRIVE; the motor is not fully engaged (insert it without forcing); or build-up on the piston and stack.
- 1007 (107, 117): foreign material in the MAV/NHBP valve, or binding in its piston and stack, reduction gears, drive gear interface or black drive pinion.
Parts Clack's fixes call for
The WS1 and WS1.25 share the drive end but use different pistons and spacer stacks. Confirm your body size with the Clack WS1 vs WS1.25 parts identification guide before ordering internals.
| Part | WS1 | WS1.25 |
|---|---|---|
| Control-valve motor | V3107-01 motor assembly | |
| Drive cap assembly | V3004 drive cap assembly, with V3135 drive cap O-ring | |
| Main piston | V3011 downflow or V3011-01 upflow | V3407 downflow |
| Regenerant piston (softeners) | V3174 regenerant piston | |
| Spacer stack | V3005-02 EPDM spacer stack | V3430 spacer stack |
| PC board | Match your controller: V3108, V3818TC or V3408EE-02BOARD | |
For a 1.25-inch valve, see the Clack WS1.25 parts hub. To see every Clack internal by function, use the Clack control valve service parts guide, or browse the Clack WS1 parts collection.
Problems without a code
- Water running to drain: water softener keeps draining.
- Salt level not dropping: softener will not draw brine.
- Meter not counting gallons: Clack WS1 meter assembly vs turbine assembly.
Before you order
- Write down the code exactly as displayed and whether it returns after resynchronizing.
- Confirm WS1 or WS1.25, and downflow or upflow, from the valve label.
- Note the board type: button count and whether it is a time clock (TC) or metered control.
- Look up the full part number in the exact part-number index, or send the label through help me find my part.
Frequently asked questions
What does Err 1001 mean on a Clack WS1?
The control cannot sense the motor turning. Clack lists three causes: the motor is not fully engaged or its wires are disconnected, the PC board is not snapped into the drive bracket, or reduction gears are missing.
Are Err 101, Err 1001 and E1 the same fault?
Yes. Clack's manual groups them as one code; the display depends on the board generation. The same applies to 102/1002/E2 and 103/1003/E3.
How do I reset a Clack error code?
Hold NEXT and REGEN together for 3 seconds, or unplug the power for 5 seconds, to resynchronize the board with the piston. If the code returns, the cause is still present.
Does error 1003 mean I need a new piston?
Not always. Check the motor connections and that the drive bracket is snapped in first. Clack calls for new piston and stack assemblies when build-up on them causes enough drag to time out the motor.
Why does my WS1 show error 1006 when it has no alternating valve?
The control is likely programmed for ALT A, ALT b, nHbP, SEPS or AUX MAV without that valve attached. Resynchronize, then reprogram the valve to the correct setting.
Sources